Hawker 800XP Pro Line 21
Page 4-8
Pilot’s Operating Manual
Revision A1: Nov, 2002
Section III - SYSTEMS DESCRIPTION
Sub-section 4
FIRE PROTECTION
BCF PORTABLE FIRE EXTINGUISHER
A single portable hand-operated extinguisher, stowed on the flight compartment left bulkhead, provides
BCF extinguishant for fighting fires in the interior of the fuselage.
A second BCF extinguisher is located in the passenger cabin in a location determined by the cabin
layout.
Either extinguisher is suitable for the following types of fires:
• Vaporized liquids such as kerosene, hydraulic fluid and similar.
• Electrical fires.
• The early stages of fires involving freely burning materials such as wood, paper and cloth.
The extinguishant is a charge of 1.5 kg of BCF (Halon 1211) propelled by a pressurized charge of dry
nitrogen. Operation of the extinguisher is controlled by a manual trigger. A safety catch is on the
mounting bracket to prevent operation of the trigger when the extinguisher is stowed. The extinguisher
is retained in the mounting bracket by a strap and fastener.
Releasing the trigger interrupts the flow and seals the nozzle to prevent any leakage of extinguishant.
NOTE: A re-charged extinguisher must be installed in the airplane once an extinguisher has been
completely or partially used.
Figure 3
BCF Portable Fire Extinguisher