Page 9-6
140-590032-0007
Revision A4: Sep, 2010
Section III Sub-section 9
ELECTRICAL POWER
Pilot’s Operating Manual
VOLTMETER
A 0-40V voltmeter and selector switches are provided in the flight compartment on the overhead roof
panel. The voltmeter scale has a red segment between 32V and 40V. The voltmeter may display, by
selection on the switches, the voltage of the batteries (1 thru 6), busbars PE, PS1 or PS2. The positions
on the switches are labelled B1, PS1, PE, PS2, B2, XFER and B3, B4, B5, B6, OFF.
EXT BATT CHG ON/OFF switch
The No. 1 battery is charged from the PS1 busbar, and No. 2 battery is charged from the PS2.
As a generator comes on-line, the associated battery contactor closes automatically and the charge
begins. The batteries may also be charged from an external power source by selecting the EXT BATT
CHG switch to ON.
Rates of charges should be monitored on the generator ammeters during external charging and when
the charge rate drops to less than 5 AMPS the EXT BATT CHG switch should be selected OFF.
During external charging, if the power supply voltage rises or falls beyond preset limits, the charging will
automatically terminate.
Overhead Roof Panel
1
111
10
20
30
40
DC
v
PS1
PE
PS2
B1
B2
DC VOLTS
B4
B5
B6
B3
OFF
XFER
OFF
ON
EXT BATT CHG
Overhead Roof Panel