ELECTRICAL POWER
Pilot’s Operating Manual
APU GENERATOR (if APU installed)
The generator driven by the APU is rated at 28 VDC at 250 AMPS. When the APU is running, operating
the APU GEN switch, located on the APU control panel - vestibule panel inner face, to CLOSE and held
for 5 seconds causes the APU generator contactor to close. The electrical output of the APU is
connected to PS2 busbar and selecting the BUS TIE switch to CLOSE also connects the APU output
to PS1.
OVERVOLTAGE PROTECTION
The GCU overvoltage protection circuit operates when the generator terminal voltage rises above 32.5
VDC. This opens the generator field and signals the GLC to open, disconnecting the generator from its
busbar.
+
+
-
STARTER BUSBAR
PS2 BUSBAR
PS1 BUSBAR
No. 1
STARTER
GEN
No. 2
STARTER
GEN
APU
STARTER
GEN
APU START
GEN LINE
CONTACTOR
No. 2
GEN LINE
CONTACTOR
No. 1
PE BUSBAR
BATT 1
BATT 2
INTERNAL START
CONTACTOR
EMERGENCY CONTACTORS
PE 2
GEN SHUNT
No. 1
GEN SHUNT
No. 2
APU GEN
SHUNT
EXTERNAL POWER
CONTACTOR
TO PS2(a) and PS2(b)
BUSBARS
TO PS1(a) and PS1(b)
BUSBARS
OPERATING
ENG 2
GEN 2
FAIL
GEN 1
FAIL
PWR ON
PUSH FOR
ABORT
POWER
DIODE
POWER
DIODE
POWER
DIODE
POWER
DIODE
OPERATING
ENG 1
Figure 8
APU (if installed) Generator On-Line