Page 9-20
140-590032-0007
Revision A4: Sep, 2010
Section III Sub-section 9
ELECTRICAL POWER
Pilot’s Operating Manual
AC POWER
AC power is supplied from two sources:
• DC driven static inverters
• Engine driven alternators
CONTROLS and INDICATIONS
All controls and indicators, with the exception of the ELECT repeater annunciator on the MWS panel,
are located on the AC POWER section of the overhead roof panel. The main inverter START-STOP
switches are three position switches, spring-loaded to the center position.
The illumination of the XE FAIL annunciator will also result in the red flashing MWS master warning
lamps on the glareshield to operate. The ELECT repeater annunciator will flash when any of the
following annunciators illuminate:
The AC VOLTS indicator is calibrated to read from 50 to 150 VAC. Its face has a red segment from 50
volts to 100 volts and another red segment from 130 volts to 150 volts.
Voltage on busbars XS 1, XE and XS 2 may be displayed by selection of the associated voltmeter rotary
switch.
AC POWER
1
111
100
120
AC
v
60
80
140
XE
XS1 XS2
STBY INV
ARM
INV 1
START
INV 2
START
STOP
OFF
STOP
XS 1
FAIL
XS 2
FAIL
XE
FAIL
INV 1
FAIL
INV 2
FAIL
STBY INV
ON
XFER
OFF
B6
B5
B4
B3
ELECT
Repeater annunciator flashes
MWS panel
Overhead Roof Panel