Page 2-33
Pilot’s Operating Manual
Revision A2: Nov, 2004
Sub-section 2
GROUND SERVICING
Hawker 800XP Pro Line 21
Section VI - GROUND OPERATIONS
Gravity Refuel Ventral Tank Procedure
(1) Check the VENTRAL tank contents legend on the CDU displays EMPTY.
(2) Check the AUX FUEL TRANSFER valve is shut (lever up).
(3) Bond the refuel vehicle or hydrant to the airplane.
(4) Comply with local refueling safety precautions.
(5) Open the gravity refuel access door in the ventral tank rear fairing (Figure 10).
(6) Bond the filling nozzle to the bonding spigot on the tank.
(7) Remove the filler cap from the tank.
(8) Pump fuel into the tank until full and withdraw the nozzle.
(9) Check the filler cap is serviceable, install and secure the cap to the tank. Disconnect
the bonding lead and close the access door.
(10) Check the VENTRAL tank contents legend on the CDU displays FULL.
(11) Disconnect the refuel vehicle or hydrant bonding lead.
(12) If the POWER switch on the refuel control panel was selected to ON, select the
POWER switch to OFF.
(13) Check the overhead roof panel REFUEL ON annunciator is extinguished.
(14) If necessary, de-energize DC busbars.
(15) Drain water from the tank.
CAUTION:
LEAVE THE AUX FUEL TRANSFER VALVE SHUT OR FUEL MAY TRANSFER FROM
THE VENTRAL TANK TO THE WING TANKS.
(16) Refuel all other tanks as required for flight.