7-12
745 Transformer Management Relay
GE Multilin
7.3 MODBUS FUNCTIONS
7 COMMUNICATIONS
7
c) FUNCTION CODE 06H SUBSTITUTION
Function code 06h (Store Single Setpoint) is simply a shorter version of function code 10h (Store Multiple Setpoints). Using
function code 10h, such that the Number of Setpoints stored is 1, has the same effect as function code 06h. The message
format and example is shown below.
Request slave device 11 to write the single setpoint value 00C8 at setpoint address 1100.
7.3.7 MEMORY MAP ORGANIZATION
Data in the 745 that is accessible via computer communications is grouped into several sections of the memory map as
shown in the table below. All memory map locations are two-byte (16-bit) values. The following section lists all memory map
locations. Addresses for all locations are in hexadecimal. Consult the range, step, units, and the data format (listed after the
memory map) to interpret the register values.
MASTER QUERY MESSAGE:
EXAMPLE (HEX):
SLAVE ADDRESS
11
query message for slave 11
FUNCTION CODE
10
store multiple setpoints (substituted for code 06H)
DATA STARTING ADDRESS: high order byte, low order byte
11 00
data starting at address 1100
NUMBER OF SETPOINTS: high order byte, low order byte
00 01
1 setpoint values = 2 bytes total
BYTE COUNT
02
2 bytes of data
DATA: high order byte, low order byte
00 C8
data for address 1100 = 00C8
CRC: low order byte, high order byte
6B 07
CRC computed by master
SLAVE RESPONSE:
EXAMPLE (HEX):
SLAVE ADDRESS
11
response message from slave 11
FUNCTION CODE
00
store multiple setpoint values
DATA STARTING ADDRESS: high order byte, low order byte
11 00
data starting at address 1100
NUMBER OF SETPOINTS: high order byte, low order byte
00 01
1 setpoint values = 2 bytes total
CRC: low order byte, high order byte
06 65
CRC computed by slave
Table 7–4: MEMORY MAP ORGANIZATION
MEMORY MAP SECTION
ADDRESS RANGE
DESCRIPTION
Product ID
0000 to 007F
Identification and revision information. Read only.
Commands
0080 to 00FF
Substitute command locations. Read and write.
User Map
0100 to 01FF
User Map Values and Addresses. Read and write.
Actual Values
0200 to 07FF
Read only.
Event Recorder
0800 to 0FFF
Read only (except "Event Record Selector Index").
Common Setpoints
1000 to 1FFF
Read and write.
Setpoint Group 1/2/3/4
2000 to 3FFF
Read and write.
Trace Memory
4000 to 47FF
Read only (except "Trace Buffer Selector Index" and "Trace Channel Selector
Index")
Playback Memory
4800 to 4FFF
Read and write.