Commands Manual

Software Version PVP- 3.0.1

For

 

PVP Shelf P/N 002-0800-00

Document 250-0800-06
Version A1
May 2008

Copyright 2008 Ditech Networks

 

www.ditechnetworks.com

VQA  Enabled

TM

TM

Содержание Packet Voice Processor

Страница 1: ...et Voice Processor Commands Manual Software Version PVP 3 0 1 For PVP Shelf P N 002 0800 00 Document 250 0800 06 Version A1 May 2008 Copyright 2008 Ditech Networks www ditechnetworks com VQA Enabled T...

Страница 2: ...both print and illustrations Tests have shown that the quality of documentation is best when a printout is generated from a native source e g floppy disk or CD ROM and printed on a high quality laser...

Страница 3: ...tronic Mail support ditechnetworks com Telephone 1 800 770 0117 Toll Free USA and Canada 1 650 864 1800 Direct Fax 1 650 564 9843 Order Status Product Availability and Product Pricing Electronic Mail...

Страница 4: ...Notes TM iv 250 0800 06 Version A1 D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m...

Страница 5: ...ice Processor Commands Manual Document Number 250 0800 06 or product model number Shipping information including customer name and address Contact information for the person requesting the manual Dite...

Страница 6: ...cument Title Packet Voice Processor Commands Manual Document Number 250 0800 06 Document Version Version A1 May 2008 Products for which the comments and corrections are applicable The comments and cor...

Страница 7: ...Module RTM 002 0821 00 1 Media Processing cards 002 0830 00 5 Interface Processing cards 002 0810 32 4 Shelf Managers 002 0800 02 2 Peripheral Controller Modules 002 0800 03 2 Power Entry Modules PEM...

Страница 8: ...tles are shown in bold italics with initial capital letters Example Network Operations Manual BOLD ALL CAPS Command names are shown in bold uppercase Example the DATE and TIME commands Capitalized Key...

Страница 9: ...ist of Figures xxi List of Tables xxiii List of Examples xxvii 1 Introduction 1 Overview 1 PVP Hardware Components 2 Card and Slot Compatibility 4 Network Interfaces 5 Media Interface Features 6 Signa...

Страница 10: ...OOB Ports Signaling Provisioning 37 Switch Control Card Redundancy 39 Ethernet Media Ports Provisioning 40 4 Voice Quality Provisioning 43 Overview 43 Provisioning Commands 43 Provisioning Steps 44 5...

Страница 11: ...Software 82 Reverting to Previous Software 82 Setting up Autonomous Alarms 83 Switching Cards 84 Switching System Control Cards 84 Switching Media Processing Cards 84 Switching Application Processing...

Страница 12: ...face Commands 130 INTERFACE media port SHOW Command 130 INTERFACE media port SET Command 131 INTERFACE media port SET admin state Command 131 INTERFACE media port STATS SHOW Command 132 INTERFACE medi...

Страница 13: ...E REMOVE Command 164 SYSTEM VQ REPORT metric family HIST bin SHOW Command 165 SYSTEM CALL REPORT HIST bin SHOW Command 167 CRAFT Command 168 ALARMSEV Commands 169 ALARMSEV SHOW Command 169 ALARMSEV SE...

Страница 14: ...ommand 207 VER IPMC Command 208 LOAD Command 209 CUTOVER Command 209 CUTOVER sccslot Command 209 REVERT Command 210 REVERT sccslot Command 210 CLONE Command 211 ISUSTAT Command 212 In Service Software...

Страница 15: ...AYLOADTYPE PROFILE SHOW Command 243 PAYLOADTYPE PROFILE ADD Command 243 PAYLOADTYPE PROFILE DEFAULT SHOW Command 247 PAYLOADTYPE PROFILE payload profile name SHOW Command 248 PAYLOADTYPE PROFILE paylo...

Страница 16: ...r op value Command 304 THRESHOLD type RULE thr rule name COND metric DEL Command 305 THRESHOLD type PROFILE SHOW Command 305 THRESHOLD type PROFILE ADD Command 306 THRESHOLD type PROFILE ADD new thr p...

Страница 17: ...Section 371 Metric Definition Section 371 Metric Status Section 373 Call Data Section 374 18 Security Commands 381 Overview 381 PASSWORD Commands 382 PASSWORD user SHOW Command 382 PASSWORD user SET...

Страница 18: ...atistics 409 UDP Statistics 411 IP Statistics 411 ARP Statistics 412 ICMP Statistics 413 IGMP Statistics 413 Signaling Port Statistics 415 TCP Statistics 415 UDP Statistics 417 IP Statistics 417 ARP S...

Страница 19: ...n Progress 183 477 SIP Message 14 Session in Progress 183 477 SIP Messages 15 and 16 478 SIP Message 15 REGISTER Message 479 SIP Message 16 Success Message 200 479 SIP Messages 17 and 18 480 SIP Messa...

Страница 20: ...S w w w d i t e c h n e t w o r k s c o m Notes TM Support 497 Overview 497 Warranty Policy 497 Equipment Repair and Return 498 Packet Voice Processor Packaging Instructions 498 Ditech s Return Addres...

Страница 21: ...OB Signaling Interface 37 Figure 3 2 Interface Processing Card Gigabit Ethernet Interface 40 Figure 5 1 Profile Policy VQA Application Schematic 47 Figure 5 2 PVP and SIP Proxy Server Schematic 50 Fig...

Страница 22: ...65 Figure F 6 SIP Messages 5 to 10 471 Figure F 7 SIP Messages 11 and 12 475 Figure F 8 SIP Messages 13 and 14 476 Figure F 9 SIP Messages 15 and 16 478 Figure F 10 SIP Messages 17 and 18 480 Figure F...

Страница 23: ...ng Port Provisioning 39 Table 3 5 Media Ports Provisioning Commands 40 Table 3 6 Media Ports Provisioning 41 Table 4 1 Voice Quality Provisioning Commands 43 Table 4 2 Voice Quality Provisioning 44 Ta...

Страница 24: ...e 10 12 Link Aggregation Group Commands 137 Table 10 13 LAG ROUTE Commands 138 Table 10 14 LAG lag index SHOW Command Output 140 Table 10 15 LAG PING Command 141 Table 10 16 LAG lag index STATS SHOW C...

Страница 25: ...ues 320 Table 16 2 R factor to MOS Conversion Values 320 Table 16 3 MOS CQ Data Parameter Definitions 322 Table 16 4 MOS LQ Data Parameter Definitions 325 Table 16 5 R factor Value Ranges 328 Table 16...

Страница 26: ...e D 3 IP Statistics Management Port 411 Table D 4 ARP Statistics Management Port 412 Table D 5 ICMP Statistics Management Port 413 Table D 6 IGMP Statistics Management Port 413 Table D 7 TCP Statistic...

Страница 27: ...NTORY CARD Command 100 Example 9 15 INVENTORY CARD 3 Command 101 Example 9 16 INVENTORY FAN fan Command 103 Example 9 17 INVENTORY PEM pem Command 105 Example 9 18 INVENTORY perictrlr perictrlr Comman...

Страница 28: ...ip name Command 146 Example 10 36 LAG lag index IP DEL Command 147 Example 10 37 LAG lag interface PORT SHOW Command 147 Example 10 38 LAG lag index PORT ADD Command 148 Example 10 39 LAG lag index P...

Страница 29: ...mand 184 Example 11 2 PROTECT MPC slot Command 184 Example 11 3 PROTECT APC Command 184 Example 11 4 RELEASE SCC Command 185 Example 11 5 RELEASE MPC Command 185 Example 11 6 RELEASE APC Command 186 E...

Страница 30: ...ROUTE route name SHOW Command 228 Example 13 14 SIGNALING PROFILE profile name ROUTE route name SET Command 229 Example 13 15 SIGNALING PROFILE profile name ROUTE route name DEL Command 229 Example 13...

Страница 31: ...profile name SET Command 278 Example 14 7 VQA PROFILE DEL Command 279 Example 14 8 VQA PROFILE CLONE Command 279 Example 15 1 FILTER SHOW Command 284 Example 15 2 FILTER ADD Command 285 Example 15 3...

Страница 32: ...5 Example 16 1 MOS CQ Data Output 321 Example 16 2 MOS LQ Data Output 324 Example 16 3 R CQ Data Output 329 Example 16 4 R LQ Data Output 332 Example 16 5 SPEECH Data Output 336 Example 16 6 NOISE Dat...

Страница 33: ...Progress 183 477 Example F 14 SIP Message 14 Session in Progress 183 477 Example F 15 SIP Message 15 REGISTER Message 479 Example F 16 SIP Message 16 Success Message 200 479 Example F 17 SIP Message...

Страница 34: ...xxxiv 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m Notes TM...

Страница 35: ...g to packet based voice traffic Figure 1 1 The Packet Voice Processor can be deployed by both wireline and wireless service providers to process packet voice flows in a variety of applications and net...

Страница 36: ...ssifies and routes certain specific in band signaling packets for example PING or trace route packets to the call processor on the SCC Media Processing cards MPCs These cards contain the DSPs to proce...

Страница 37: ...rd Function Diagram Interface Processing Cards Switch Control Cards 2x GB 2x GB 2x GB 2x GB Media Processing Card Connections to Media Network Media Processing Card Media Processing Card Media Process...

Страница 38: ...ing Card itself consists of a carrier board with up to four installed Processor PCI Mezzanine Cards PrPMCs each housing two processors Note that the card slots are not numbered sequentially left to ri...

Страница 39: ...shelf slot 14 has the protection role Note Both Interface Processing cards have working roles Redundancy is provided by LAG Link Aggregation Group provisioning for these card types see Section 10 6 o...

Страница 40: ...e Switch Control card has the following features for out of band SIP RFC 3261 call control and signaling 1000Base T Ethernet interface at half or full duplex with auto negotiation Support for static I...

Страница 41: ...on page 387 1 3 1 PVP SIP Signaling The Packet Voice Processor s Switch Control card supports the SIP call processing function as well as switching policy treatment and enforcement The Packet Voice P...

Страница 42: ...s sent to the outbound SIP proxy In some situations an inbound SIP proxy or other inbound network element may also make the routing decisions In these situations the inbound SIP proxy adds one or more...

Страница 43: ...ork through broadband access The calls originate on an IP telephone or on a media terminal adapter MTA connected to an analog device in the enterprise The voice calls are assumed to be under the contr...

Страница 44: ...d forwards the INVITE to the SIP server SIP Proxy 2 in the network that controls the routing of the call to its end destination PSTN 6 The Packet Voice Processor acts as a termination point for the SI...

Страница 45: ...ket loss delay and jitter Figure 1 7 displays a schematic of a possible Packet Voice Processor deployment within an IP network as well as how the VQA and IPR technologies would improve the call Figure...

Страница 46: ...alls based upon route customer or defined service policy With the Packet Voice Processor operating as a centralized transcoding resource at the IP network border providers avoid the expense of low den...

Страница 47: ...0 ms interruption in transmission of each digit must be supported If the interruption in transmission is longer than 10 ms which is the case of bursty networks then the DTMF transmission should not be...

Страница 48: ...RC and SMV CODECs EVRCB0 CODEC and associated options are not supported in this release Note For additional information please refer to the above mentioned RFCs 1 4 1 2 2 EVRC0 Modes When performing t...

Страница 49: ...the update is performedevery 20 mS and if set to 255 the update is performed every 5 1 seconds If the dtxmin parameter is not present then the algorithm assumes a default value of 12 only if silence...

Страница 50: ...s caused by the conversion point also known as the hybrid between the 4 wire and 2 wire transmission facilities The hybrid connects the 4 wire carrier facility to the 2 wire access line within a switc...

Страница 51: ...wide range of echo variances using algorithms based on talker energy levels bulk delay and Weighted Acoustic Echo Path Loss WAEPL to effectively eliminate acoustic echo and significantly improve voice...

Страница 52: ...h without distorting or amplifying the signal Note VQA technology is further described in detail in Chapter 14 on page 265 1 4 3 Intelligent Packet Restoration IPR IPR is an advanced feature that reco...

Страница 53: ...the ability to locate the ultimate source of a network problem and the ability to handle the problem to reduce cost and help generate revenues EXi solutions analyze the voice quality measurement resu...

Страница 54: ...these environments the VoIP Tandem Carrier must convert the signal between different VoIP codec formats measure voice quality to ensure compliance with regulatory mandates or service level agreements...

Страница 55: ...ments for impairments introduced through packet transport voice codec operations and environmental noise The Packet Voice Processor corrects for both packet loss and jitter within an ITSP environment...

Страница 56: ...k as well as how the VQA and IPR technologies would improve the call Figure 1 12 PVP Placement within a VoIP Wholesaler Network Clearer VoIP Calls Clearer TDM Calls Media Gateway Media Gateway Level M...

Страница 57: ...ection 2 10 on page 34 Autonomous Packet Voice Processor System Messages Section 2 11 on page 34 2 2 Connecting to the PVP The Packet Voice Processor CLI is accessible through either the serial port l...

Страница 58: ...n the Switch Control card s front panel when first configuring a Packet Voice Processor system A single system management Ethernet port is provided on the back of the Packet Voice Processor shelf chas...

Страница 59: ...and auto negotiation Table 2 2 describes the process for connecting to and logging onto the Switch Control card through the Ethernet connection Note The procedure outlined in Table 2 2 on page 25 pre...

Страница 60: ...s RTM connector until you hear a click indicating that the connectors are engaged 4 Connect the opposite end of the RJ 45 cable to an available port on the Local Area Network LAN Allow enough cable f...

Страница 61: ...Switch Controller Card s front face panel Refer to this chapter for detailed instructions Provision the System Management port located on the active Switch Controller Card Refer to Chapter 3 for detai...

Страница 62: ...a Packet Voice Processor system A single system management Ethernet port is provided on the back of the Packet Voice Processor shelf chassis via the Rear Transition Module RTM The process for connect...

Страница 63: ...ble 6 3 Link Aggregation Group Commands on page 64 lists the commands required for this procedure 12 If applicable provision the DNS server for the Packet Voice Processor system If the Packet Voice Pr...

Страница 64: ...erience Intelligence EXi Commands Chapter 15 on page 281 Security Commands Chapter 18 on page 383 2 5 HELP Command Packet Voice Processor commands that are available and displayed to the user are depe...

Страница 65: ...TIMEZONE SYSTEM COMMANDS AUTOMSG LAG CARDS SYSTEM FPKG SNMP DNS INTERFACE NTP CRAFT ALARMSEV MAINTENANCE COMMANDS RELEASE EVENTHIST MGMTDB ALARMHIST ALARMS SIGCAP ACO PROTECT VERSION CONTROL COMMANDS...

Страница 66: ...ple users with Admin level privileges can access all commands and change all user passwords while users with Read level access privileges can only view data and are unable to change the status of the...

Страница 67: ...or CLI supports interactive command menus to simplify command configuration with multiple parameters The UP and DOWN arrows as well as the hyphen and ENTER keys can be used to navigate the command men...

Страница 68: ...LI supports a minimum of 100 command history sessions per log in session The UP and DOWN arrows can be used to navigate this list The Packet Voice Processor logs all executed commands in persistent st...

Страница 69: ...outer This port is only accessible through an Ethernet port located on the back of the PVP shelf chassis via the Rear Transition Module RTM Table 3 1 System Management Port Provisioning Commands Comma...

Страница 70: ...service See Section 10 2 1 on page 115 for additional command information 3 Enter the INTERFACE mgmt port SHOW command Enter this command to view the current management port s configuration Most of th...

Страница 71: ...an OOB Out of Band Signaling Interface Sig O that is a physical port located on each Switch Control card This signaling interface provides a dedicated channel for system signaling The Packet Voice Pr...

Страница 72: ...onal command information see Section 10 4 4 on page 123 INTERFACE sig port IP sigip index DEL Delete an IP address from the signaling interface The required minimum access level is WRITE for this comm...

Страница 73: ...with multiple routers ARP messages are sent every x seconds to a user defined IP device To set up this redundant configuration the Next Hop IP Device parameter see Table 3 4 on page 39 is provisioned...

Страница 74: ...g Card Gigabit Ethernet Interface Table 3 5 displays the commands used for provisioning the Packet Voice Processor Gigabit Ethernet media ports on the Interface Processing cards IPC Table 3 5 Media Po...

Страница 75: ...ate Experience Intelligence EXi report for media interface The required minimum access level is READ for this command For additional command information see Section 10 5 6 on page 134 Table 3 6 Media...

Страница 76: ...42 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m Notes TM...

Страница 77: ...The required minimum access level is READ for this command For additional command information see Section 14 1 on page 265 VQA PROFILE SHOW Command that displays a list of VQA profiles The required m...

Страница 78: ...ioning Commands Continued Command Description Table 4 2 Voice Quality Provisioning Step Task Description 1 Access the Packet Voice Processor system Establish a connection to the active Switch Control...

Страница 79: ...re 2 types of Packet Voice Processor signaling commands commands used to provision signaling for a Packet Voice Processor profiles and policies and commands used to capture and display the accumulated...

Страница 80: ...s from SIP Proxy 192 168 0 10 and applies SigProfile01 IP Signaling Address 10 67 1 240 Port 5070 accepts packets from SIP Proxy 192 168 0 11 and applies SigProfile02 IP Signaling Address 10 67 1 280...

Страница 81: ...creates a profile and does not create a policy for it default settings are applied to the IP media packet stream see Section 5 4 1 on page 55 Note Table 5 2 on page 51 and Table 5 4 on page 54 descri...

Страница 82: ...see Section 13 5 5 on page 224 SIGNALING PROFILE profile name SHOW Command that displays a signaling profile The required minimum access level is READ for this command For additional information see S...

Страница 83: ...112 to the IP address 10 67 1 240 and signaling port number 5060 on the active Switch Control card of the Packet Voice Processor SIGNALING PROFILE profile name ROUTE route name SHOW Command that disp...

Страница 84: ...mmand and involves setting up the connections between the signaling port on the active Switch Control card and the egress Packet Voice Processor SIP proxy server where out bound PVP SIP signaling pack...

Страница 85: ...W command Enter this command to review any factory configured signaling profiles and polices See Section 13 5 1 on page 219 for additional command information 4 Enter the SIGNALING PROFILE ADD command...

Страница 86: ...g the PVP for the above SIP messages are also attached to the same messages exiting the PVP If disabled headers pass unprocessed through the Packet Voice Processor Note Enabling Proprietary Header Pas...

Страница 87: ...CS OSPS DCS Billing ID DCS Billing Info Rpid Privacy Caller Preference Support Headers All Caller Preference Support headers will pass through These include the following header types Accept Contact R...

Страница 88: ...creating a profile route Table 5 4 Profile Route Provisioning Step Task Description 1 Enter the SIGNALING PROFILE profile name ROUTE ADD command Enter this command to add a new route to the signaling...

Страница 89: ...ofile also be configured Note The PVP Can Support a maximum of 40 Signaling Profiles If a user creates a signaling profile without creating a signaling policy a system default setting will be applied...

Страница 90: ...ional information see Section 13 7 2 on page 232 SIGNALING POLICY ADD Command that adds a signaling policy The required minimum access level is WRITE for this command For additional information see Se...

Страница 91: ...TE for this command For additional information see Section 13 4 on page 218 SIGNALING POLICY policy name THRESHOLD PROFILE REMOVE Command that removes the threshold profile attached to signaling polic...

Страница 92: ...IP messages from SIDE 1 becomes SIDE 2 In Figure 5 3 below this device is the Media Gateway After a call is setup media bearer traffic from Side 1 is transcoded from Codec 1 to Codec 2 Media bearer tr...

Страница 93: ...Voice Processor supports both SIP signaling and RTP RTCP media streams between a caller and callee Figure 6 1 The Packet Voice Processor uses Link Aggregation Groups LAGs and LACP to increase the medi...

Страница 94: ...is a method where multiple physical links are combined into a single logical link This provides the following important features increased link capacity and redundancy Link aggregation provides both...

Страница 95: ...e how many LAGs will be required for the Packet Voice Processor installation 3 Determine the number of Interface Processing cards that will be used in the Packet Voice Processor installation for the b...

Страница 96: ...acket Voice Processor requires at least 1 network interface IP address for signaling purposes Switch Router or Routers For the Management IP network A Packet Voice Processor network configuration may...

Страница 97: ...em management and signaling functions being combined in a single switch router or signaling and the bearer media IP network functions combined in a single switch router Figure 6 2 PVP Network Planes T...

Страница 98: ...vel is WRITE for this command For additional information see Section 10 6 9 on page 143 LAG lag index STATS SHOW Command that displays the LAG interface statistics The required minimum access level is...

Страница 99: ...inimum access level is READ for this command see Section 10 6 21 LAG ROUTE SHOW Command on page 150 LAG ROUTE ADD Command that adds a static entry to the LAG routing table The required minimum access...

Страница 100: ...ovisioning Example Section 6 4 1 on page 66 Redirection Static LACP Mode Section 6 4 2 on page 69 PVP Configuration with HSRP VRRP Fail Over Section 6 4 3 on page 70 6 4 1 LAG Provisioning Example For...

Страница 101: ...w d i t e c h n e t w o r k s c o m 6 Media Provisioning Packet Voice Processor Commands Manual Figure 6 3 Static LAG Configuration PWR A1 PWR A2 PWR B1 PWR B2 GigE 4 1 Active GigE 4 2 Standby GigE 6...

Страница 102: ...g 5 Enter the LAG ADD command Enter this command to add a new LAG interface See Section 10 6 5 on page 141 for additional command information 6 Enter the LAG lag index IP ADD command Enter this comman...

Страница 103: ...he standby port s configured with the alternative role e g Master to Backup or Backup to Master 9 Physically connect or patch the Interface Processing card s ports to the router designated as Master i...

Страница 104: ...by routers send periodic HSRP messages once the protocol has completed the election process If the active router fails the standby router takes over as the active router If the standby router fails or...

Страница 105: ...port using the Packet Voice Processor commands could lead to congestion on the active LAG port or ports in the event of a LAG port failure Note The Packet Voice Processor LAG redirection is non rever...

Страница 106: ...ns up For example at the reader s left in this diagram see location A in the figure the 4 Gigabit Ethernet ports are provisioned as follows GigE 4 1 Active Master GigE 4 2 Standby Backup GigE 6 1 Acti...

Страница 107: ...ve Backup GigE 4 1 GigE 4 2 GigE 6 1 GigE 6 2 Active Master Inactive Backup Active Master Inactive Backup GigE 4 1 GigE 4 2 GigE 6 1 GigE 6 2 Standby Master Active Backup Standby Master Inactive Backu...

Страница 108: ...up or down it does not affect the IP connection to the next hop device For example at location A in this diagram the 4 Gigabit Ethernet ports are provisioned as follows GigE 4 1 Standby Master GigE 4...

Страница 109: ...Inactive Master Active Backup GigE 4 1 GigE 4 2 GigE 6 1 GigE 6 2 Inactive Master Standby Backup Active Master Inactive Backup GigE 4 1 GigE 4 2 GigE 6 1 GigE 6 2 Inactive Master Active Backup Standby...

Страница 110: ...76 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m Notes TM...

Страница 111: ...384 PASSWORD user SET Command that sets the password for given user The required minimum access level is ADMIN for this command see Section 18 2 2 on page 384 PASSWORD user CLR Command that clears a p...

Страница 112: ...ar all passwords through the access level method requires Admin access level privileges Users with other access levels can only change or clear their own passwords All logins are prompted for a user I...

Страница 113: ...the CMDLOG command and output The output for this command displays the date time stamp access level the port IP address and the commands issued Example 7 1 CMDLOG Command PVP CMDLOG COMMAND LOG 26 Apr...

Страница 114: ...80 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m Notes TM...

Страница 115: ...the main features of the Packet Voice Processor is the ease of in service software upgrades The Version Control commands control software upgrades for both the Switch Control card and other cards Tab...

Страница 116: ...interrupts voice quality enhancement provided by the VQA and IPR technologies This command should only be issued during a maintenance window For additional REVERT command information see Section 12 5...

Страница 117: ...ous Message PVP Alarm Set Slot 2 INT DATA LINK 13 EQP MJ 27 Apr 06 07 33 12 12 Alarm Clr Slot 2 INT DATA LINK 13 EQP MJ 27 Apr 06 07 33 15 12 PVP Alarm Set Slot 1 STANDBY EXT SIG LINK FAC MJ 27 Apr 06...

Страница 118: ...ic card slot see Section 11 2 2 on page 184 for additional information To switch back to the original Media Processing card enter the RELEASE MPC slot command see Section 11 3 2 on page 185 for additi...

Страница 119: ...ard Failure In the event of a Media Processing card failure the Packet Voice Processor will respond in stages as described in Table 8 6 on page 85 Note Only a single Media Processing card can be prote...

Страница 120: ...dia Processing card in slot 13 and switches to protect the Media Processing card in slot 11 see Figure 8 2 on page 87 Note that when Media Processing card in slot 11 fails the ACT LED on this card s f...

Страница 121: ...essing Card Media Processing Card Media Processing Card Media Processing Card Switch Control Card Switch Control Card Interface Processing Card Media Processing Card Media Processing Card Interface Pr...

Страница 122: ...88 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m Notes TM...

Страница 123: ...1 HELP HELP Command PVP HELP HELP HELP Syntax HELP List commands available to current user HELP TABLE Display table of available user commands HELP CLI Show information about features of the command...

Страница 124: ...ommand PVP help table The following commands are available GENERAL COMMANDS HELP TIME LAMP INVENTORY DATE CMDLOG TIMEZONE SYSTEM COMMANDS AUTOMSG LAG CARDS SYSTEM FPKG SNMP DNS INTERFACE NTP CRAFT ALA...

Страница 125: ...le command syntaxes beginning with the specified sequence COMMAND LINE EDITING A command line can be edited using BACKSPACE INSERT or DELETE COMMAND HISTORY Use the Up and Down arrows on the command l...

Страница 126: ...ault WRITE level CALLSTATS SHOW Show call statistics READ level CALLSTATS CLR Clear call statistics WRITE level CALLSTATS profile name SHOW Show call statistics for profile READ level CALLSTATS profil...

Страница 127: ...NERAL category Example 9 5 HELP category Command PVP HELP GENERAL CMDLOG SHOW Display the command log READ level CMDLOG CLR Clear the command log WRITE level DATE SHOW Display the current date READ le...

Страница 128: ...the time enter the time using the 24 hour clock format where the morning hours 12 00 A M to 11 59 A M are from 00 00 to 11 59 and the afternoon evening night hours 12 00 P M to 11 59 P M are from 12...

Страница 129: ...COMMAND LOG 26 Apr 2006 14 43 08 CRAFT Serial LAG 1 PORT ADD GIGE 6 2 26 Apr 2006 14 43 07 CRAFT Serial LAG 1 PORT ADD GIGE 6 1 26 Apr 2006 14 43 02 CRAFT Serial LAG 1 PORT ADD GIGE 4 4 26 Apr 2006 14...

Страница 130: ...ommand The LAMP slot STAT command displays the hue status for the LED on a given card The color codes include OFF RED YEL yellow GRN green AMB amber BLU blue BSB blue short blink BLB blue long blink B...

Страница 131: ...ORY Command The INVENTORY commands display the inventory information for a selected shelf shelf components or card slot The minimum access level for this command is Read The command syntax is as follo...

Страница 132: ...e to either the card or shelf but the card will not activate Warning In a non redundant Switch Control card configuration only one Switch Control card in the shelf the single Switch Control card must...

Страница 133: ...ng card MPC 5 Media Processing card MPC 3 Media Processing card MPC 1 Switch Control card SCC 2 Switch Control card SCC 4 Interface Processing card IPC 6 Interface Processing card IPC 8 Application Pr...

Страница 134: ...RY CARD command and output Example 9 14 INVENTORY CARD Command PVP INVENTORY CARD Card 1 Inventory Data Serial No SWSRF0600097 Assembly Part Numr 1 03 Assembly Hw Revision 010 0820 0 Top Assembly Part...

Страница 135: ...0830 03 Top Assembly Revision 4x CLEI CLEI Warranty Expires 08 22 2009 Note For information about this command s parameters refer to Table 9 4 on page 101 Table 9 4 INVENTORY CARD Command and Output C...

Страница 136: ...r this command is Read The command syntax is as follows INVENTORY FAN fan Blower Module 1 FAN 1 is the module located in the right slot top when directly facing the front of the Packet Voice Processor...

Страница 137: ...Assembly Part Num 002 0820 03 Top Assembly Revision 1 06 CLEI PVLabMountViewCA Warranty Expires 08 22 2006 FAN 4 Inventory Data Serial No SWSRF0600094 Assembly Part Num 010 0820 3 Assembly Hw Revisio...

Страница 138: ...ler located in the next left slot second from the left when directly facing the back of the Packet Voice Processor Power Entry Module 3 PEM 3 is the module located in the next left slot third from the...

Страница 139: ...s 02 01 2009 PEM 2 Inventory Data Serial No PEMDG1900026 Assembly Part Num 02A001524 Assembly Hw Revision B03 Top Assembly Part Num 002 0800 04 Top Assembly Revision A1 CLEI NGPUSD0TAA Warranty Expire...

Страница 140: ...able 9 6 INVENTORY PEM pem Command and Output Command Output Description Serial Number Factory created serial number Assembly Part Num Factory created assembly part number Assembly Hw Revision Factory...

Страница 141: ...4 Figure 9 4 Peripheral Controller Modules The minimum access level for this command is Read The command syntax is as follows INVENTORY PERICTRLR perictrlr Entering this command without an argument di...

Страница 142: ...0 Top Assembly Revision 1 06 CLEI PVLABMTVIEW Warranty Expires 08 22 2006 Table 9 7 describes the INVENTORY perictrlr perictrlr command output Go To For additional Packet Voice Processor Peripheral Co...

Страница 143: ...for the 2 shelf managers Shelf Manager 1 SHMC 1 is the shelf manager located in the left slot when directly facing the front of the Packet Voice Processor Shelf Manager 2 SHMC 2 is the shelf manager l...

Страница 144: ...le 9 8 INVENTORY SHMC shmc Command and Output Command Output Description Serial Number Factory created serial number Assembly Part Num Factory created assembly part number Assembly Hw Revision Factory...

Страница 145: ...RY SAP sap Entering this command without an argument displays information for the 2 shelf managers Shelf Manager 1 SHMC 1 is the shelf manager located in the left slot when directly facing the front o...

Страница 146: ...112 250 0800 06 Version A D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m General Commands Packet Voice Processor Commands Manual...

Страница 147: ...6 and Section 3 2 on page 35 Signaling Port see Section 10 4 on page 121 and Section 3 3 on page 37 Media Port see Section 10 5 on page 130 and Section 3 4 on page 40 LAG Command that displays or sets...

Страница 148: ...ort SET admin state Set signaling interface administrative state INTERFACE sig port IP ADD Add IP Address to signaling interface INTERFACE sig port IP sigip index DEL Delete IP Address to signaling in...

Страница 149: ...ACE SHOW Example 10 1 below displays an example of this command and output The physical interfaces and status are displayed in the command output There are 3 interface types ports in a Packet Voice Pr...

Страница 150: ...this command and output Example 10 2 INTERFACE mgmt port SHOW Command PVP INTERFACE MGMT 0 SHOW Administrative State IS OOS Operational Status IS MAC Address 00 D0 02 10 04 20 Configured Speed Auto 1...

Страница 151: ...d Output Command Output Description Administrative State Displays the port s administrative state IS is defined as In Service Normal OOS is defined as Out of Service Operational Status Displays whethe...

Страница 152: ...ACE mgmt port SET admin state Command PVP INTERFACE MGMT 0 SET IS Provisioned 10 3 4 INTERFACE mgmt port STATS SHOW Command The INTERFACE mgmt port STATS SHOW command displays the management interface...

Страница 153: ...Statistics Statistic Description ifIndex For internal use debugging purposes only ifDescr ifType ifMtu ifSpeed ifAdminStatus ifOperStatus ifLastChange ifInOctets Number of bytes received by the inter...

Страница 154: ...cket This is the pattern sent in the ICMP packet that is used to debug data related problems in the network 10 3 6 INTERFACE mgmt port ARP SHOW Command The INTERFACE mgmt port ARP SHOW command shows t...

Страница 155: ...port IP SHOW Section 10 4 7 on page 124 INTERFACE sig port STATS SHOW Section 10 4 8 on page 126 INTERFACE sig port PING interval pattern packetsize pinghost Section 10 4 9 on page 128 INTERFACE sig p...

Страница 156: ...Mbps Configured Gateway Configured Gateway address Slot 1 Actual Port Speed Actual Ethernet interface speed in Mbps SCC slot 1 Slot 1 Actual Port Duplex Actual duplex mode for the Ethernet interface...

Страница 157: ...ort SET admin state Command The INTERFACE sig port SET admin state command sets the signaling interface administrative state The administrative state can be set to IS in service or OOS out of service...

Страница 158: ...sig port IP ip addr DEL Command The INTERFACE sig port IP ip addr DEL command deletes an IP address from the signaling interface The required minimum access level is Write for this command The comman...

Страница 159: ...nds 250 0800 06 Version A 125 D I T E C H N E T W O R K S w w w d i t e c h n e t w o r k s c o m 10 System Commands Packet Voice Processor Commands Manual 6 10 62 1 242 255 255 255 0 7 10 62 1 243 25...

Страница 160: ...CE sig port STATS SHOW Example 10 15 displays this command and partial output Command output is organized and displayed per protocol statistic type Example 10 15 INTERFACE sig port STATS Command PVP I...

Страница 161: ...ts received at the signaling port ifInNUcastPkts Number of non unicast packets received at the signaling port ifInDiscards Number of discarded packets received at the signaling port ifInErrors Number...

Страница 162: ...pab s100 10 67 1 111 PATTERN 0xab PING 10 67 1 111 10 67 1 111 100 data bytes 108 bytes from 10 67 1 111 icmp_seq 0 ttl 255 time 2 ms 108 bytes from 10 67 1 111 icmp_seq 1 ttl 255 time 0 ms 108 bytes...

Страница 163: ...ade with respect to the SIP profile and policy configurations The required minimum access level is Read for this command The command syntax is as follows INTERFACE sig port ARP SHOW Example 10 17 disp...

Страница 164: ...d minimum access level is Read for this command The command syntax is as follows INTERFACE media port SHOW Example 10 18 displays an example of this command and output Example 10 18 INTERFACE media po...

Страница 165: ...Command PVP INTERFACE GIGE 6 4 SET Setup Dialog Navigate with arrow keys Ctrl C to abort Administrative State IS OOS OK TO USE Yes No Y Provisioned Note For information about this command s parameters...

Страница 166: ...at are collected using this command Table 10 11 Media Port Statistics Statistic Description RxRtpRtcpPkt Number of RTP and RTCP packets received at the selected Media bearer port RxErroredPkt Number o...

Страница 167: ...E media port STATS CLR Example 10 22 displays an example of this command and output Example 10 22 INTERFACE media port STATS CLR Command PVP INTERFACE GIGE 4 1 STATS CLR Done MarkerTxCt Transmitted LA...

Страница 168: ...CE media port QOS REPORT HIST bin SHOW Example 10 23 displays an example of this command and output Example 10 23 INTERFACE media port QOS REPORT Command PVP INTERFACE GIGE 4 1 QOS REPORT Media Interf...

Страница 169: ...the 802 3 frame structure Link aggregation is also completely transparent to all upper layer protocols The Packet Voice Processor supports up to four static LAGs 10 6 1 Static LAG The Packet Voice Pr...

Страница 170: ...mands Manual Figure 10 1 Link Redundancy Application Link Aggregation Group 1 Link Aggregation Group 2 Link Aggregation Group 3 Link Aggregation Group 4 GigE 4 1 GigE 4 3 GigE 4 4 GigE 6 1 GigE 6 2 Gi...

Страница 171: ...mand on page 143 LAG lag index STATS SHOW Command that displays the LAG interface statistics The required minimum access level is READ for this command see Section 10 6 10 LAG lag index STATS SHOW Com...

Страница 172: ...mmand that adds a static entry static route to the Packet Voice Processor LAG routing table The Packet Voice Processor LAG routing table uses the entry as an egress point The required minimum access l...

Страница 173: ...splays an example of this command and output Example 10 24 LAG SHOW Command PVP LAG SHOW LAG KEY MODE MAXPORTS PORTS Lag 1 1 Static N A GigE 6 1 GigE 6 2 Entering the LAG SHOW command with its LAG ind...

Страница 174: ...ts VRRP or HSRP like redundancy LAG IPs Name User created index number Address IP address for the LAG Mask IP Subnet Mask address for the LAG Minimum UDP Ports Minimum number of UDP ports used for the...

Страница 175: ...eters for this command Note The Next Hop Device IP value in the above command example is only used for supporting a VRRP redundant router protection scheme 10 6 6 LAG PING The LAG PING command sends P...