176 | Using RAPIDS and Rogue Classification
Dell PowerConnect W-AirWave 7.6 | User Guide
Threat level and classification are both assigned to a device when a device matches a rule. Once classified, a device’s
classification and threat level change only if it is classified by a new rule or is manually changed. Threats levels can be
manually defined on the
RAPIDS > Detail
page when the RAPIDS classification is manually overridden or you can
edit the rule to have a higher threat level.
Viewing and Configuring RAPIDS Rules
To view the RAPIDS rules that are currently configured on AirWave, navigate to the
RAPIDS > Rules
page (
Figure
119
).
Figure 119:
RAPIDS > Rules
Page Illustration
Table 98
defines the fields in the
RAPIDS > Rules
page.
Field
Description
Default Classification
This drop down specifies the classification that a rogue device receives when it does not
match any rules.
Add New RAPIDS
Classification Rule
Select this button to create a RAPIDS classification rule.
Rule Name
Displays the name of any rule that has been configured. Rule names should be descriptive
and should convey the core purpose for which it was created.
Classification
Displays the classification that devices receive if they meeting the rule criteria.
Threat Level
Displays the numeric threat level for the rogue device that pertains to the rule. Refer to
"Rogue Device Threat Level" on page 175
for additional information.
Enabled
Displays the status of the rule, whether enabled or disabled.
Reorder Drag and Drop Icon
Changes the sequence of rules in relation to each other. Select, then drag and drop, the icon
for any rule to move it up or down in relation to other rules. A revised sequence of rules must
be saved before rogues are classified in the revised sequence.
NOTE:
The sequence of rules is very important for proper rogue classification. A device gets
classified by the first rule to which it complies, even if it conforms to additional rules later in
the sequence.
Table 98:
RAPIDS > Rules Page
Содержание PowerConnect W-AirWave 7.6
Страница 1: ...Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 12: ...xii Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 112: ...100 Configuring and Using Device Groups Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 162: ...150 Discovering Adding and Managing Devices Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 198: ...186 Using RAPIDS and Rogue Classification Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 276: ...264 Creating Running and Emailing Reports Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 324: ...312 Using VisualRF Dell PowerConnect W AirWave 7 6 User Guide ...
Страница 332: ...320 Index Dell PowerConnect W AirWave 7 6 User Guide ...