Selection number
Selection name
Description
0
Absolute
Absolute value is considered as threshold
1
Offset
Calculates threshold as sum of the computed baseline data and the offset values
2
Factor
Calculates threshold as baseline data factor
10.550 (ID 3517) Current Warning S1 High
Location in the menu:
P2.13.3.4.2
(Multi-purpose Control Application)
Use this parameter to set the threshold value for computing the warning 1 high notification threshold. Threshold value range varies
based on warning mode selection. This limit is not used when value is zero.
10.551 (ID 3518) Current Warning S1 Delay
Location in the menu:
P2.13.3.4.3
(Multi-purpose Control Application)
Use this parameter to define how long time the actual value must be above the warning S1 notification level to trigger the warning
S1. This level is not used when delay is zero.
10.552 (ID 3519) Current Warning S2 Mode
Location in the menu:
P2.13.3.4.4
(Multi-purpose Control Application)
Use this parameter to select the warning S2 mode which is used for calculating warning S2 notification threshold.
Selection number
Selection name
Description
0
Absolute
Absolute value is considered as threshold
1
Offset
Calculates threshold as sum of the computed baseline data and the offset values
2
Factor
Calculates threshold as baseline data factor
10.553 (ID 3520) Current Warning S2 High
Location in the menu:
P2.13.3.4.5
(Multi-purpose Control Application)
Use this parameter to set the threshold value for computing the warning 2 high notification threshold. Threshold value range varies
based on warning mode selection. This limit is not used when value is zero.
10.554 (ID 3521) Current Warning S2 Delay
Location in the menu:
P2.13.3.4.6
(Multi-purpose Control Application)
Use this parameter to define how long time the actual value must be above the warning S2 notification level to trigger the warning
S2. This level is not used when delay is zero.
10.555 (ID 3522) Current Alarm/Fault Mode
Location in the menu:
P2.13.3.4.7
(Multi-purpose Control Application)Current Alarm/Fault Mode (ID 3522)
Use this parameter to select the alarm/fault mode which is used for calculating alarm/fault notification threshold.
Selection number
Selection name
Description
0
Absolute
Absolute value is considered as threshold
1
Offset
Calculates threshold as sum of the computed baseline data and the offset values
2
Factor
Calculates threshold as baseline data factor
10.556 (ID 3523) Current Alarm/Fault High
Location in the menu:
P2.13.3.4.8
(Multi-purpose Control Application)
AB296635287482en-000301 / DPD00903 | 297
Danfoss A/S © 2023.02
Parameter Descriptions
VACON® NX All-in-One
Application Guide