Motor voltage corresponding to 40% of flux as a percentage of nominal flux voltage.
10.490 (ID 1359) Flux 50%
Location in the menu:
P2.6.18.5
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.5
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 50% of flux as a percentage of nominal flux voltage.
10.491 (ID 1360) Flux 60%
Location in the menu:
P2.6.18.6
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.6
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 60% of flux as a percentage of nominal flux voltage.
10.492 (ID 1361) Flux 70%
Location in the menu:
P2.6.18.7
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.7
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 70% of flux as a percentage of nominal flux voltage.
10.493 (ID 1362) Flux 80%
Location in the menu:
P2.6.18.8
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.8
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 80% of flux as a percentage of nominal flux voltage.
10.494 (ID 1363) Flux 90%
Location in the menu:
P2.6.18.9
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.9
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 90% of flux as a percentage of nominal flux voltage.
10.495 (ID 1364) Flux 100%
Location in the menu:
P2.6.18.10
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.10
(Multi-purpose Control Application, VACON
®
NXP)
Use this parameter to set the level of flux as a percentage of the nominal flux voltage.
Motor voltage corresponding to 100% of flux as a percentage of nominal flux voltage.
10.496 (ID 1365) Flux 110%
Location in the menu:
P2.6.18.11
(Multi-purpose Control Application, VACON
®
NXS)
P2.6.17.11
(Multi-purpose Control Application, VACON
®
NXP)
AB296635287482en-000301 / DPD00903 | 287
Danfoss A/S © 2023.02
Parameter Descriptions