Audit Events and Alarms
AUDIT (19)
To monitor and correct the cause of the event, refer to the
“Recovered Memory of Stale Call—Audit
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
for
detailed instructions on contacting Cisco TAC and opening a service request.
Prior to contacting Cisco TAC, collect a trace log corresponding to the time of the alarm.
DESCRIPTION
Recovered Memory of Stale Call
SEVERITY
WARNING
THRESHOLD
20
THROTTLE
0
DATAWORDS
Stale Memory Release Info–STRING [128]
PRIMARY
CAUSE
A loss of communication with originating or terminating side has occurred.
PRIMARY
ACTION
Check to see if adjacent network element is up and has a proper communication link with the BTS
10200.
SECONDARY
CAUSE
Adjacent network device protocol error has occurred.
SECONDARY
ACTION
Check the adjacent network device protocol compatibility.
TERNARY
CAUSE
An internal software error has occurred.
TERNARY
ACTION
Contact Cisco Support. (Contact Cisco TAC.)