![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550266.webp)
7-34
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (61)
To troubleshoot and correct the cause of the alarm, refer to the
“No Heartbeat Messages Received
Through the Interface—Maintenance (61)” section on page 7-102
MAINTENANCE (62)
To troubleshoot and correct the cause of the alarm, refer to the
Communication—Maintenance (62)” section on page 7-103
.
DESCRIPTION
No Heartbeat Messages Received Through the Interface (No HB Messages Received Through the
Interface)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Interface Name–STRING [20]
Interface IP Address–STRING [50]
PRIMARY
CAUSE
The local network interface is down.
PRIMARY
ACTION
Restore the local network interface.
SECONDARY
CAUSE
The mate network interface on the same sub-net is faulty.
SECONDARY
ACTION
Restore the mate network interface.
TERNARY
CAUSE
Network congestion.
DESCRIPTION
Link Monitor: Interface Lost Communication
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Interface Name–STRING [80]
Interface IP Address–STRING [80]
PRIMARY
CAUSE
The interface cable is pulled out or the interface is set down using
ifconfig down
command.
PRIMARY
ACTION
Restore the network interface.
SECONDARY
CAUSE
The interface has no connectivity to any of the machines or routers.