![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 403](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550403.webp)
10-35
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (64)
To troubleshoot and correct the cause of the alarm, refer to the
“Media Gateway Adapter Running out of
Shared Memory Pools—Signaling (64)” section on page 10-138
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
SIGNALING (65)
To troubleshoot and correct the cause of the alarm, refer to the
“Media Gateway Adapter Running out of
Heap Memory—Signaling (65)” section on page 10-138
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Media Gateway Adapter Running out of Shared Memory Pools (MGA Running out of Shared Memory
Pools)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
Issued when the Media Gateway Control Protocol (MGCP) signaling adapter was unable to allocate
data storage for an inter-process communication (IPC) message due to a lack of resources.
PRIMARY
ACTION
Call Cisco TAC technologies for assistance. (Contact Cisco TAC.)
DESCRIPTION
Media Gateway Adapter Running out of Heap Memory (MGA Running out of Heap Memory)
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
Issued when the MGCP signaling adapter was unable to allocate data storage for an IPC message from
the heap due to a lack of resources.
PRIMARY
ACTION
Call Cisco TAC Technologies for assistance. (Contact Cisco TAC.)