![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 374](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550374.webp)
10-6
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (8)
To troubleshoot and correct the cause of the alarm, refer to the
“Session Initiation Protocol Message
Receive Failure—Signaling (8)” section on page 10-131
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
for
detailed instructions on contacting Cisco TAC and opening a service request.
SIGNALING (9)
To troubleshoot and correct the cause of the alarm, refer to the
Address—Signaling (9)” section on page 10-131
DESCRIPTION
Session Initiation Protocol Message Receive Failure (SIP Message Receive Failure)
SEVERITY
MAJOR
THRESHOLD
30
THROTTLE
0
DATAWORDS
Reason Text–STRING [50]
PRIMARY
CAUSE
Operating system level network errors have occurred or an invalid network configuration exists.
PRIMARY
ACTION
Have your network administrator resolve the network errors. Contact Cisco TAC if you need
assistance. Manually clear the alarm. Restart this call agent instance using the
platform start
command.
DESCRIPTION
Timeout on Internet Protocol Address (Timeout on IP Address)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
MGW/Term Name–STRING [80]
Gateway Type–STRING [32]
Possible Cause–STRING [32]
PRIMARY
CAUSE
Issued when opticall is unable to communicate with a gateway.
PRIMARY
ACTION
Verify that the gateway is both configured for service and that it has been set in service.
SECONDARY
ACTION
Attempt to ping the gateway using the Internet Protocol (IP) address from the event report. If the ping
is not successful, then diagnose the issue that prevents the address from being reached.
TERNARY
ACTION
Use the status media gateway (MGW) identification (ID) = xxx, where xxx is the IP address given in
the event report. If the status is not in service (INS), then use the
control mgw
command to put it in
service.