Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 6 Database Troubleshooting
Database Events and Alarms
DATABASE (18)
To monitor and correct the cause of the event, refer to the
Interaction—Database (18)” section on page 6-25
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DATABASE (19)
For additional information, refer to the
“Daily Database Backup Completed Successfully—Database
DESCRIPTION
Unexpected Runtime Data Interaction
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Internal/External In–STRING [10]
Table Name–STRING [32]
Table Entry–STRING [10]
Table Field Name–STRING [32]
Descriptive Data 1–STRING [64]
Descriptive Data 2–STRING [64]
Descriptive Data 3–STRING [64]
Descriptive Data 4–STRING [64]
PRIMARY
CAUSE
An unexpected data interaction has been detected at the runtime in the call agent or the feature server.
PRIMARY
ACTION
Collect the logs and contact Cisco Support. (Contact Cisco TAC.)
DESCRIPTION
Daily Database Backup Completed Successfully
SEVERITY
INFO
THRESHOLD
0
THROTTLE
0
DATAWORDS
Host Name–STRING [60]
ORACLE_SID–STRING [30]
Process–STRING [60]
Message 1–STRING [100]
Message 2–STRING [100]
Message 3–STRING [100]
PRIMARY
CAUSE
Normal operation.
PRIMARY
ACTION
N/A