![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 376](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550376.webp)
10-8
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (12)
To troubleshoot and correct the cause of the alarm, refer to the
“Feature Server is not Up or is not
Responding to Call Agent—Signaling (12)” section on page 10-132
SIGNALING (13)
To troubleshoot and correct the cause of the alarm, refer to the
“Signaling System 7 Signaling Link
Down—Signaling (13)” section on page 10-133
DESCRIPTION
Feature Server is not Up or is not Responding to Call Agent
SEVERITY
CRITICAL
THRESHOLD
30
THROTTLE
0
DATAWORDS
Domain Name of FS–STRING [65]
Feature Server ID–STRING [20]
PRIMARY
CAUSE
The feature server platform is down or is not operating properly.
PRIMARY
ACTION
Restart the applicable feature server.
DESCRIPTION
Signaling System 7 Signaling Link Down (SS7 Signaling Link Down)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Link_Number–ONE_BYTE
Link_Name–STRING [25]
PRIMARY
CAUSE
The Signaling System 7 (SS7) trunk group may be out-of-service (OOS).
PRIMARY
ACTION
Use the
control ss7-trunk-grp
command to place the trunk group in service (INS).
SECONDARY
CAUSE
The local Ulticom stack may be down.
SECONDARY
ACTION
Run the Ulticom stack again.
TERNARY
CAUSE
The SS7 link may be disconnected or faulty.
TERNARY
ACTION
Check the Ulticom local configuration.
SUBSEQUENT
CAUSE
The remote SS7 signaling site may be down or incorrectly configured.
SUBSEQUENT
ACTION
Check the Ulticom remote configuration.