10-30
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (53)
For additional information, refer to the
“Set Trunk State as Remotely Blocked—Signaling (53)” section
SIGNALING (54)
For additional information, refer to the
“Circuit Validation Test Aborted—Signaling (54)” section on
.
DESCRIPTION
Set Trunk State as Remotely Blocked
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when the specified CIC is marked as remotely blocked due to the CQM response indicating that
it is remotely blocked at the far end.
PRIMARY
ACTION
Clear the blocking situation at the far end based on network level event reports.
DESCRIPTION
Circuit Validation Test Aborted
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when the circuit specified failed a validation test due to an internal failure.
PRIMARY
ACTION
Verify that the SS7 signaling adapter process and that the SS7 interface are operating normally.