![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 136](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550136.webp)
3-30
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 3 Billing Troubleshooting
Monitoring Billing Events
All Billing Links at Billing Server Down—Billing (35)
The All Billing Links at Billing Server Down alarm (critical) indicates that all of the billing links to the
billing server are down. To troubleshoot and correct the cause of the All Billing Links at Billing Server
Down alarm, refer to the
“All Billing Links at Billing Server Down—Billing (35)” section on page 3-39
.
Billing Link Restored—Billing (36)
The Billing Link Restored event is informational and no further action is required. The primary cause of
the Billing Link Restored event is that the cable to the billing server or the link to the billing server has
been restored.
Billing Link Failure—Billing (37)
The Billing Link Failure alarm (major) indicates that a link to the billing server has failed. To
troubleshoot and correct the cause of the Billing Link Failure alarm, refer to the
Failure—Billing (37)” section on page 3-40
Event Message Log File Access Error—Billing (38)
The Event Message Log File Access Error alarm (major) indicates that an event message (EM) log file
access error has occurred. To troubleshoot and correct the cause of the Event Message Log File Access
Error alarm, refer to the
“Event Message Log File Access Error—Billing (38)” section on page 3-40
.
Event Message Encode Failure—Billing (40)
The Event Message Encode Failure alarm (minor) indicates that an EM encode failure has occurred. To
troubleshoot and correct the cause of the Event Message Encode Failure alarm, refer to the
Message Encode Failure—Billing (40)” section on page 3-40
Message Content Error—Billing (41)
The Message Content Error alarm (minor) indicates that a message content error has occurred. To
troubleshoot and correct the cause of the Message Content Error alarm, refer to the
Error—Billing (41)” section on page 3-40
.