![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 246](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550246.webp)
7-14
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (18)
To troubleshoot and correct the cause of the alarm, refer to the
Died—Maintenance (18)” section on page 7-97
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
for
detailed instructions on contacting Cisco TAC and opening a service request.
MAINTENANCE (19)
To troubleshoot and correct the cause of the alarm, refer to the
“Process Manager: Process Exceeded
Restart Rate—Maintenance (19)” section on page 7-98
.
DESCRIPTION
Process Manager: Process has Died (PMG: Process has Died)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Process Name–STRING [40]
Process Group–FOUR_BYTES
PRIMARY
CAUSE
This alarm is caused by a software problem.
PRIMARY
ACTION
If problem persists, contact Cisco TAC technical support. (Contact Cisco TAC.)
DESCRIPTION
Process Manager: Process Exceeded Restart Rate (PMG: Process Exceeded Restart Rate)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Process Name–STRING [40]
Restart Rate–FOUR_BYTES
Process Group–ONE_BYTE
PRIMARY
CAUSE
This alarm is usually caused by a software problem on the specific platform identified in the alarm
report. Soon after this event is issued, one platform will go to the faulty state.
PRIMARY
ACTION
Review the information from CLI log report.
SECONDARY
ACTION
Restart the platform identified in the alarm report.
TERNARY
ACTION
If platform restart is not successful, reinstall the application for this platform, and then restart platform
again.
SUBSEQUENT
ACTION
If necessary, reboot the host machine this platform is located on. Then reinstall and restart all
applications on this machine.