Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (108)
To monitor and correct the cause of the event, refer to the
Transferred—Maintenance (108)” section on page 7-87
MAINTENANCE (109)
To troubleshoot and correct the cause of the alarm, refer to the
“Five Successive Log Files Cannot be
Transferred—Maintenance (109)” section on page 7-110
.
DESCRIPTION
A Log File Cannot be Transferred
SEVERITY
WARNING
THRESHOLD
5
THROTTLE
0
DATAWORDS
Name of the File With Full Path–STRING [100]
External Archive System–STRING [50]
PRIMARY
CAUSE
A problem in access to the external archive system has occurred.
PRIMARY
ACTION
Check the external archive system.
SECONDARY
CAUSE
The network to the external archive system is down.
SECONDARY
ACTION
Check the network.
TERNARY
CAUSE
The source log file is not present.
TERNARY
ACTION
Check the presence of log file.
DESCRIPTION
Five Successive Log Files Cannot be Transferred
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
External Archive Systems–STRING [100]
PRIMARY
CAUSE
A problem in access to external archive system has occurred.
PRIMARY
ACTION
Check the external archive system.
SECONDARY
CAUSE
Network to the external archive system is down.
SECONDARY
ACTION
Check the network.