Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Monitoring Signaling Events
Continuity Recheck is Performed on Specified Circuit Identification
Code—Signaling (44)
The Continuity Recheck is Performed on Specified Circuit Identification Code event functions as an
informational alert that a continuity recheck was performed on the specified CIC. The event is
informational and further action is required.
Circuit is UNEQUIPPED on Remote Side—Signaling (45)
The Circuit is UNEQUIPPED on Remote Side event functions as an informational alert the circuit is
unequipped on the remote side. The primary cause of the event is that an unequipped circuit has been
detected on the remote side. To correct the primary cause of the event, monitor the event reports at the
network level to verify if an existing circuit was unequipped causing a status mismatch with the local
end.
Specified Circuit Identification Code is Invalid for the Operation—Signaling
(46)
The Specified Circuit Identification Code is Invalid for the Operation event functions as an
informational alert that the specified CIC in invalid for the attempted operation. The primary cause of
the event is that an invalid operation was performed on the specified CIC. To correct the primary cause
of the event, verify that the SS7 provisioning tables are properly configured at the circuit level.
A General Processing Error Encountered—Signaling (49)
The A General Processing Error Encountered event functions as a informational alert that a general
processing error has occurred. The primary cause of the event is that a general SS7 processing error
occurred due to all resources being busy or an invalid event occurring. To correct the primary cause of
the event, verify the status of the signaling adapter process and the SS7 signaling interface to verify
proper operation.
Unexpected Message for the Call State is Received: Clear Call—Signaling (50)
The Unexpected Message for the Call State is Received: Clear Call event functions as an informational
alert that an unexpected message for the call state has been received. The primary cause of the even is
that an unexpected message was received for the current call state. To correct the primary cause of the
event, verify the status of the signaling adapter process and the SS7 signaling interface to verify proper
operation.
Set Trunk State as Remotely Unequipped—Signaling (51)
The Set Trunk State as Remotely Unequipped event functions as an informational alert that the trunk
state is currently set as remotely unequipped. The primary cause of the event is that the specified CIC is
marked at remotely unequipped due to the CQM response indicating that it is unequipped at the far end.
To correct the primary cause of the event, equip the trunk circuit at the far end.