10-45
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (83)
To troubleshoot and correct the cause of the alarm, refer to the
Socket—Signaling (83)” section on page 10-140
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
SIGNALING (84)
To troubleshoot and correct the cause of the alarm, refer to the
Limit—Signaling (84)” section on page 10-140
DESCRIPTION
Error While Binding to Socket
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Gateway ID–STRING [32]
Socket ID–FOUR_BYTES
Local TSAP Address–STRING [32]
Reason–STRING [128]
PRIMARY
CAUSE
An error has occurred while binding to a socket.
PRIMARY
ACTION
Contact Cisco TAC.
DESCRIPTION
Reached Maximum Socket Limit
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Gateway ID–STRING [32]
Active Sockets–FOUR_BYTES
PRIMARY
CAUSE
The configuration setting of an H.323 signaling adapter (H3A) parameter in the platform.cfg file is
wrong.
PRIMARY
ACTION
Reconfigure the platform.cfg file and restart the H3A process.