Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 3 Billing Troubleshooting
Billing Events and Alarms
BILLING (31)
To troubleshoot and correct the cause of the alarm, refer to the
“Port not Specified—Billing (31)” section
BILLING (32)
To troubleshoot and correct the cause of the alarm, refer to the
“Element Management System Address
not Specified—Billing (32)” section on page 3-39
DESCRIPTION
Port not Specified
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
Port not specified in the platform.cfg file.
PRIMARY
ACTION
Check platform.cfg file and add the argument to blg -port 15260.
DESCRIPTION
Element Management System Address not Specified (EMS Address not Specified)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
PRIMARY
CAUSE
Either the primary or secondary EMS address has not been specified in the platform.cfg file.
PRIMARY
ACTION
Check the platform.cfg for the process billing (BLG) and add the missing addresses to the file.