Troubleshooting Signaling Alarms
Link is Congested—Signaling (16)
The Link is Congested alarm (minor) indicates that the SS7 link is congested. The primary cause of the
alarm is that the specified SS7 link is experiencing congestion. To correct the primary cause of the alarm,
monitor event reports at the network level to determine if the traffic load on the specified SS7 link is too
high on the local end, or if the remote end is lagging in processing the traffic. Verify that the SS7 link
has not degraded in quality. Verify that the traffic load has not become unbalanced if multiple SS7 links
are used. Verify that local SS7 signaling adapter process is running normally.
Link: Local Processor Outage—Signaling (17)
The Link: Local Processor Outage alarm (minor) indicates that the SS7 link has experienced a local
processor outage. The primary cause of the alarm is that the specified SS7 link has experienced a
processor outage. To correct the primary cause of the alarm, monitor the system for maintenance event
reports associated with the signaling adapter or underlying platform instance that support the specified
SS7 link. Verify that the pocess and or platform are restarted and returned to service.
Link: Remote Processor Outage—Signaling (18)
The Link: Remote Processor Outage alarm (minor) indicates that the SS7 link has experienced a remote
processor outage. The primary cause of the alarm is that the specified SS7 link has experienced a
processor outage. To correct the primary cause of the alarm, monitor the network level event reports for
any events associated with the processing complex used by the specified SS7 link. Verify that the SS7
link is returned to service.
Link Set Inaccessible—Signaling (19)
The Link Set Inaccessible alarm (major) indicates that the specified SS7 link in inaccessible. The
primary cause of the alarm is that the specified SS7 link set is inaccessible. To correct the primary cause
of alarm, return the SS7 signaling adapter and the associated call agent platform to service if the SS7
signaling adapter is not running normally and the associated call agent platform is not active.
Link Set Congestion—Signaling (20)
The Link Set Congestion alarm (major) indicates that the specified SS7 link set is congested. The
primary cause of the alarm is that the specified SS7 link set is experiencing congestion. To correct the
primary cause of the alarm, monitor the alarm and event reports at the network level to determine if the
traffic load on the specified SS7 link set is too high on the local end, or if the remote end is lagging in
processing the traffic. Verify that the SS7 link set has not degraded in quality. Verify that the traffic load
has not become unbalanced if multiple SS7 link sets are used. Verify that local SS7 signaling adapter
process is running normally.