Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (122)
To troubleshoot and correct the cause of the alarm, refer to the
“Message Transfer Part 3 User Adapter
Cannot Go Active—Signaling (122)” section on page 10-154
SIGNALING (123)
SIGNALING (123) is not used.
SIGNALING (124)
To troubleshoot and correct the cause of the alarm, refer to the
Service—Signaling (124)” section on page 10-154
DESCRIPTION
Message Transfer Part 3 User Adapter Cannot Go Active (M3UA/SUA Cannot Go Active)
SEVERITY
MAJOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Platform ID–STRING [17]
PRIMARY
CAUSE
No ACTIVE acknowledgement messages are being received from any SG or SCTP. The associations
are probably down.
PRIMARY
ACTION
Investigate any other alarms to see if the SGs are down or the SCTP associations are down. Take
corrective action according to those alarms.
DESCRIPTION
Remote Subsystem is Out Of Service
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Destination Point Co–STRING [20]
Remote Subsystem Num–TWO_BYTES
PRIMARY
CAUSE
A link loss has occurred or the remote subsystem is out of service.
PRIMARY
ACTION
Check the links. Check the remote location, if possible.