![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 797](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550797.webp)
17-7
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 17 Disk Replacement
Call Agent/Feature Server or Element Management System Disk 0 Replacement
Step 8
Use the
cfgadm
command to determine the defective disk parameter.
Example:
secca38#cfgadm -al
Step 9
Take disk 0 offline.
<hostname>#
cfgadm -c unconfigure c1::dsk/cxt0d0
Example:
Secca38#cfgadm -c unconfigure c1::dsk/c1t0d0
Step 10
Verify that Disk 0 is offline.
Example:
secca38#cfgadm -al
secca38#tail /var/adm/messages
Nov 2 15:53:25 secca38 genunix: [ID 408114 kern.info] /pci@1f,700000/scsi@2/sd@0,0 (sd0)
offline
Step 11
Remove the defective disk and insert the new replacement disk into slot 0.
Step 12
Use the
cfgadm
command to bring the new Disk 0 on line.
<hostname>#
cfgadm -c configure c1::dsk/cxt0d0
Example:
Secca38#cfgadm -c configure c1::dsk/c1t0d0
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
CD-ROM
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t0d0
disk
connected
configured
unknown
c1::dsk/c1t1d0
disk
connected
configured
unknown
c2
scsi-bus
connected
unconfigured
unknown
usb0/1
unknown
empty
unconfigured
ok
usb0/2
unknown
empty
unconfigured
ok
Ap_Id
Type
Receptacle
Occupant
Condition
c0
scsi-bus
connected
configured
unknown
c0::dsk/c0t0d0
CD-ROM
connected
configured
unknown
c1
scsi-bus
connected
configured
unknown
c1::dsk/c1t0d0
disk
connected
unconfigured
unknown
c1::dsk/c1t1d0
disk
connected
configured
unknown
c2
scsi-bus
connected
unconfigured
unknown
usb0/1
unknown
empty
unconfigured
ok
usb0/2
unknown
empty
unconfigured
ok