Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 15 Diagnostic Tests
Channel-Associated Signaling Trunk Termination Tests
Channel-Associated Signaling Trunk Termination Tests
This section describes the tests that can be performed on channel-associated signaling (CAS) trunk
terminations. All terminations must be in the MAINT state for testing.
Step 1
Force the CAS trunk termination into MAINT state:
control cas-trunk-termination tgn-id=64; mode=forced; target-state=maint;
Step 2
Display the Test Menu.
diag cas-trunk-termination
Reply Example:
Reply: Diagnostic CAS Trunk Group Menu.
===
(1) CAS MGCP Connectivity Test
(2) CAS Termination Connection Test
(3) ALL
Note
Test #1 tests if MGCP has access to the CAS termination.
Test #2 tests if there is a path to the device (ping).
Test #3 performs tests 1 and 2.
Step 3
To perform a specific test, use the following examples as a guide:
diag cas-trunk-termination tgn-id=64;cic=1;test=1;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 64
CIC -> 1
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 0
RESULT -> TEST-SUCCESS
REASON -> PASSED: Reason: AUEP-NACK received with RespCode = 510
Reply: Diagnostic command executed.
diag cas-trunk-termination tgn-id=64;cic=1;test=2;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 64
CIC -> 1
TEST-TYPE -> ADM-TERM-CONNECTION-TEST
TEST-DURATION -> 32
RESULT -> TEST-SUCCESS
REASON -> PASS successfully.
Reply: Diagnostic command executed.
diag cas-trunk-termination tgn-id=64;cic=1;test=3;
Reply Example:
TRUNK DIAGNOSTIC TEST EXECUTED -> diag trunk
TG-NUM -> 64
CIC -> 1
TEST-TYPE -> ADM-MGW-MGCP-CONNECTIVITY-TEST
TEST-DURATION -> 11