![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 442](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550442.webp)
10-74
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (139)
For additional information, refer to the
“Signaling System 7 Trunk was Found to be in Erroneous
State—Signaling (139) (SS7)” section on page 10-119
.
SIGNALING (140)
For additional information, refer to the
“Unanswered Information Message—Signaling (140)” section
DESCRIPTION
Signaling System 7 Trunk was Found to be in Erroneous State (SS7 Trunk was Found to be in
Erroneous State)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
Near-End State–STRING [64]
Far-End State–STRING [64]
Resolution Action–STRING [64]
PRIMARY
CAUSE
A discrepancy between the local and the remote trunk states has occurred.
PRIMARY
ACTION
Automatic corrective action is enforced when using American National Standards Institute (ANSI)
ISUP.
DESCRIPTION
Unanswered Information Message (Unanswered INF Message)
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
The far-end switch is not responding to an information (INF) message with an information request
(INR) message.
PRIMARY
ACTION
Verify that the far-end switch can correctly respond to an INF message.