10-28
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (49)
For additional information, refer to the
“A General Processing Error Encountered—Signaling (49)”
.
SIGNALING (50)
For additional information, refer to the
“Unexpected Message for the Call State is Received: Clear
Call—Signaling (50)” section on page 10-104
.
DESCRIPTION
A General Processing Error Encountered
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when a general SS7 processing error occurred due to all resources being busy or an invalid event
occurring.
PRIMARY
ACTION
Verify the status of the signaling adapter process and the SS7 signaling interface to verify proper
operation.
DESCRIPTION
Unexpected Message for the Call State is Received: Clear Call
SEVERITY
INFO
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when an unexpected message was received for the current call state.
PRIMARY
ACTION
The call is cleared. Verify the status of the signaling adapter process and the SS7 signaling interface
to verify proper operation.