![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 372](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550372.webp)
10-4
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (4)
To monitor and correct the cause of the event, refer to the
“Invalid Message Received—Signaling (4)”
SIGNALING (5)
SIGNALING (5) is not used.
DESCRIPTION
Invalid Message Received
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Endpoint Name–STRING [40]
Message Type–STRING [40]
PRIMARY
CAUSE
This event is issued when a signaling adapter has received an invalid message from the specified
endpoint.
PRIMARY
ACTION
Monitor the associated signaling link to see if there is an interruption of service on the link.
SECONDARY
ACTION
If there is a communication problem, restart the link.
TERNARY
ACTION
Verify that the version of the protocol used by the device at the endpoint is consistent with the version
expected by the call agent.
SUBSEQUENT
ACTION
If there is a mismatch, then either the endpoint or call agent must be reprovisioned.