![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 259](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550259.webp)
7-27
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 7 Maintenance Troubleshooting
Maintenance Events and Alarms
MAINTENANCE (47)
To troubleshoot and correct the cause of the alarm, refer to the
“Thread Watchdog Counter Expired for
a Thread—Maintenance (47)” section on page 7-100
MAINTENANCE (48)
To troubleshoot and correct the cause of the alarm, refer to the
“Index Table Usage Exceeded Minor
Usage Threshold Level—Maintenance (48)” section on page 7-100
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Thread Watchdog Counter Expired for a Thread
SEVERITY
CRITICAL
THRESHOLD
100
THROTTLE
0
DATAWORDS
Process Name–STRING [5]
Thread Type–FOUR_BYTES
Thread Instance–FOUR_BYTES
PRIMARY
CAUSE
The alarm is caused by a software error.
PRIMARY
ACTION
No action is required. (The system will automatically recover or shutdown.)
DESCRIPTION
Index Table Usage Exceeded Minor Usage Threshold Level (IDX Table Usage Exceeded Minor Usage
Threshold Level)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
Table Name–STRING [80]
Size–FOUR_BYTES
Used–FOUR_BYTES
PRIMARY
CAUSE
Call traffic volumes is above the design limits.
PRIMARY
ACTION
Verify that the traffic is within the rated capacity.
SECONDARY
CAUSE
A software problem requiring manufacture analysis has occurred.
SECONDARY
ACTION
Contact customer support. (Contact Cisco TAC.)