![Cisco BTS 10200 Softswitch Скачать руководство пользователя страница 790](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550790.webp)
16-42
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 16 Disaster Recovery Procedures
Automatic Restart
Troubleshooting
Note
The following troubleshooting procedure can be used any time a platform side goes OOS due to a fault.
Troubleshooting of a platform shutdown can be completed using the Automatic Restart feature
saved.debug directory. When a platform shutdown occurs, useful debugging information (cores, logs,
etc.) is saved and compressed in a tar file. This file is located in the directory
<platform>/bin/saved.debug. To recover the tar file information and to clear the tar file disk space,
complete the following steps:
Step 1
Download the timestamped tar file from the saved.debug directory to a system for offline debugging. An
example filename is: saved.debug.2007_02_16__16_07_09.tar.Z.
Step 2
Remove the tar file from the disk after it is downloaded to conserve disk space.
Switchover in Progress–Maintenance (101)
The Switchover in Progress alarm (critical) indicates that a system switchover is in progress. This alarm
is issued when a system switchover is in progress either due to manual switchover (by a CLI command),
failover switchover, or automatic switchover. For additional information, refer to
.
Side Automatically Restarting Due to Fault–Maintenance (117)
The Side Automatically Restarting Due to Fault alarm (critical) indicates that a platform side is
automatically restarting due to a fault condition. This alarm indicates that an Automatic Restart is
pending and at what time it will be attempted. For additional information, refer to
.