10-14
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (24)
To troubleshoot and correct the cause of the alarm, refer to the
Congested—Signaling (24)” section on page 10-137
.
SIGNALING (25)
To monitor and correct the cause of the event, refer to the
“Unanswered Blocking Message—Signaling
DESCRIPTION
Destination Point Code Congested (DPC Congested)
SEVERITY
MINOR
THRESHOLD
100
THROTTLE
0
DATAWORDS
DPC–STRING [12]
DPC Type–ONE_BYTE
Congestion Level–ONE_BYTE
PRIMARY
CAUSE
Issued when the specified destination point code is congested.
PRIMARY
ACTION
Monitor the event reports at the network level to determine if the traffic load to the specified DPC is
too high on the local end, or if the remote end is lagging in processing the traffic.
DESCRIPTION
Unanswered Blocking Message (Unanswered BLO)
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
CIC Number–TWO_BYTES
TGN-ID–FOUR_BYTES
DPC–STRING [20]
OPC–STRING [20]
PRIMARY
CAUSE
Issued when a blocking (BLO) message was not acknowledged before the timer 13 (T13) expired for
the associated circuit identification code (CIC).
PRIMARY
ACTION
Verify that the SS7 signaling adapter processes is running normally. Verify that the call agent platform
is active.
SECONDARY
ACTION
Verify that the SS7 interface hardware is in service. Verify that the associated SS7 signaling link is
available.
TERNARY
ACTION
Verify that the T13 timer is set to an appropriate level.
SUBSEQUENT
ACTION
Verify that the SS7 link is not congested.