Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 3 Billing Troubleshooting
Troubleshooting Billing Alarms
Domain Name Mapping Failed—Billing (30)
The Domain Name Mapping Failed alarm (major) indicates that a domain name mapping has failed. The
primary cause of the alarm is that the wrong DNS server name mapping is specified in the BTS 10200
configuration files. To correct the primary cause of the alarm, check the opticall.cfg and platform.cfg
files for the correct mapping information.
Port not Specified—Billing (31)
The Port not Specified alarm (major) indicates that a port has not been specified or configured. The
primary cause of the alarm is that the port is not specified in platform.cfg file. To correct the primary
cause of the alarm, check the platform.cfg file and add the argument to blg -port 15260.
Element Management System Address not Specified—Billing (32)
The Element Management System Address not Specified alarm (major) indicates that an EMS address
has not been specified or configured. The primary cause of the alarm is that either the primary or
secondary EMS address has not been specified in the platform.cfg file. To correct the primary cause of
the alarm, check the platform.cfg file to verify the process BLG and to add the missing addresses to the
file.
File Transfer Protocol/Secure File Transfer Protocol Parameters
Invalid—Billing (33)
The File Transfer Protocol/Secure File Transfer Protocol Parameters Invalid alarm (major) indicates that
the FTP/SFTP parameters configuration is not valid or has not been fully configured. The primary cause
of the alarm is that the billing-acct-addr table is not fully provisioned with the information needed to
perform file transfers. To correct the primary cause of the alarm, check billing-acct-addr fields by using
the
show billing-acct-addr
command. For FTP file transfer, ensure that the billing-server-addr,
billing-server-directory, user-name, and password (not displayed) are provisioned. Also ensure that the
sftp-supp is set to N. For SFTP file transfer, ensure that the billing-server-addr, billing-server-directory,
and user-name are provisioned. Also ensure that the sftp-supp is set to Y.
All Billing Links at Billing Server Down—Billing (35)
The All Billing Links at Billing Server Down alarm (critical) indicates that all of the billing links to the
billing server are down. The primary cause of the alarm is that the cable connection to the Billing Server
may have been pulled out. To correct the primary cause of the alarm, restore cable connection to the
Billing Server. The secondary cause of the alarm is that an
ifconfig down
command may have been
executed on the interfaces. To correct the secondary cause of the alarm, execute an
ifconfig up
command
on the interfaces.