10-5
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 10 Signaling Troubleshooting
Signaling Events and Alarms
SIGNALING (6)
To monitor and correct the cause of the event, refer to the
“Database Module Function Call
Failure—Signaling (6)” section on page 10-98
SIGNALING (7)
To troubleshoot and correct the cause of the alarm, refer to the
“Socket Failure—Signaling (7)” section
.
Note
Refer to the
“Obtaining Documentation and Submitting a Service Request” section on page lvi
detailed instructions on contacting Cisco TAC and opening a service request.
DESCRIPTION
Database Module Function Call Failure
SEVERITY
WARNING
THRESHOLD
100
THROTTLE
0
DATAWORDS
Endpoint Name–STRING [40]
Return Code–FOUR_BYTES
Function Name–STRING [64]
Calling Function–STRING [64]
Index–FOUR_BYTES
PRIMARY
CAUSE
A signaling adapter has detected an error while accessing a database interface.
PRIMARY
ACTION
If the database that the adapter attempted to access is not available, restart the associated process.
SECONDARY
ACTION
If an incompatible versions of the signaling adapter process and the database processes are present on
the system, correct the error and restart the processes.
DESCRIPTION
Socket Failure
SEVERITY
MAJOR
THRESHOLD
30
THROTTLE
0
DATAWORDS
Reason Text–STRING [30]
PRIMARY
CAUSE
Issued when there is a failure in creating or binding to the User Datagram Protocol (UDP) socket.
PRIMARY
ACTION
Verify there is no conflict in the port assignment with other processes in the system and ensure that no
previous instance of the same process is still running.
SECONDARY
CAUSE
A software logic problem has occurred.
SECONDARY
ACTION
Contact Cisco Support. (Contact Cisco Technical Assistance Center (TAC).)