S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
4-22
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
OL-9285-05
Chapter 4 Troubleshooting Hardware
Troubleshooting Switching and Services Modules
The module status indicates the state of the module.
Table 4-10
identifies all of the different states that
a module can experience and provides a brief description of the state
.
Module Initialization Overview
When a module is inserted into the switch, the module goes through an initial start up sequence. This
sequence brings the module to a known good state before the module is declared online. The
initialization sequence includes the following steps:
•
Module Bootup, page 4-23
•
Image Download, page 4-23
•
Runtime Diagnostics, page 4-24
•
Runtime Configuration, page 4-24
•
Online and Operational, page 4-24
Most of the module related failures (such as the module not coming up, the module getting reloaded, and
so on) can be analyzed by looking at the logs stored on the switch. Use the following CLI commands to
view this information:
•
show system reset-reason module
Table 4-10
Module States
Module Status
Description
Module
Status
Condition
OK
The module is up and running.
Good
powered-down
The module has been powered down because of user configuration or because of an
error. Use the
show running-config | include poweroff
CLI command to determine
whether or not the module has been configured as powered-down. Otherwise, the
module was powered down because of an error.
If a module reports a FATAL error, the supervisor logs an exception and reboots the
module. If the supervisor reboots the module for errors three times in a one-hour
interval, the supervisor keeps the module permanently powered down.
Good
err-pwd-dn
Failed
pwr-denied
The chassis does not have enough remaining power to power up the module. Use the
show environment power
CLI command to show the current power status of the
switch.
Failed
powered-up
The module powered up and the supervisor is waiting for the module to initialize.
Transient
pwr-cycled
The module reloaded.
Transient
testing
The module has powered up and doing runtime diagnostics.
Transient
initializing
The module is receiving configuration from the supervisor.
Transient
upgrading
The module is in the process of a nondisruptive upgrade.
Transient
failure
The module has experienced a failure, but the module has not been power cycled
because the debug flag was configured. Use the debug flag to collect debug information
from the module as required by your customer support representative. Once all
necessary data is collected, reload the module by using the
reload module
CLI
command.
Failed