Example 4-8
displays the exception log that appears when a supervisor module reboots after a runtime
diagnostic failure.
Example 4-8
Exception Log for Supervisor Reboot Caused by Runtime Diagnostic Failure
switch#
show module internal exceptionlog module 6
********* Exception info for module 6 ********
exception information --- exception instance 1 ----
device id: 12
device errorcode: 0x80000020
system time: (1127917068 ticks) Wed Sep 28 14:17:48 2005
error type: FATAL error
<--------------------- exception that caused the reboot
Number Ports went bad:
1,2,3,4,5,6
exception information --- exception instance 2 ----
device id: 12
device errorcode: 0x00060a02
system time: (1127917067 ticks) Wed Sep 28 14:17:47 2005
error type: Warning
Number Ports went bad:
1,2,3,4,5,6
Example 4-9
displays the system messages on the standby supervisor module when a supervisor module
reboots after a runtime diagnostic failure.
Example 4-9
System Messages for Supervisor Reboot Caused by Runtime Diagnostic Failure
Switch#
show logging
2005 Sep 28 14:17:47 172.20.150.204 %XBAR-5-XBAR_STATUS_REPORT: Module 6 reported status
for component 12 code 0x60a02.
2005 Sep 28 14:17:59 172.20.150.204 %PORT-5-IF_UP: Interface mgmt0 on slot 5 is up
2005 Sep 28 14:18:00 172.20.150.204 %CALLHOME-2-EVENT: SUP_FAILURE