S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
4-27
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
OL-9285-05
Chapter 4 Troubleshooting Hardware
Troubleshooting Switching and Services Modules
Error Message
PLATFORM-2-PFM_LC_REGISTRATION_FAIL: Could not register with Module
[dec].
Explanation
Module registration failed.
Recommended Action
Replace the module.
Error Message
PLATFORM-2-PFM_LC_STATUS: Module [dec] powered up with [dec] status.
Explanation
Status for module that failed registration.
Recommended Action
Replace the module.
Error Message
PLATFORM-3-MOD_PWRFAIL: Module [dec] failed to power up (Serial No.
[chars]).
Explanation
The module failed to power up.
Recommended Action
Enter the
show platform internal all module
[
dec
]
CLI command to collect
more information.
Introduced
Cisco MDS SAN-OS Release 1.2(2a).
Error Message
PLATFORM-3-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to
idprom read error.
Explanation
The module cannot be powered up because of an IDPROM read error.
Recommended Action
Enter the
show platform internal all module
[
dec
]
and
show module
internal all module
[dec]
show sprom module
[
dec
][
dec
]
CLI command to read module IDPROM
contents to collect more information.
Error Message
PLATFORM-5-MOD_PWRDN: Module [dec] powered down (Serial No. [chars]).
Explanation
The module is powered down.
Enter the
show module
,
show platform internal all module[
dec
]
and
show module internal all
module [
dec
]
CLI command to collect more information if you suspect module has been powered down
due to errors.