Chapter 2 Troubleshooting Installs, Upgrades, and Reboots
Troubleshooting Cisco SAN-OS Software System Reboots
Recovery Using BIOS Setup for Supervisor-1
Note
Supervisor-2 modules do not provide access to the BIOS.
Caution
This procedure uses the
init system
command, which reformats the file system of the device. Be sure
that you have made a backup of the configuration files before you begin this procedure.
To recover a corrupted bootflash: device (
no bootable device found
message) for a switch with a single
supervisor-1 module, follow these steps:
Step 1
Connect to the console port of the required switch.
Step 2
Boot or reboot the switch.
Step 3
Press
Ctrl-C
to interrupt the BIOS setup during the BIOS memory test.
You see the netboot BIOS Setup Utility screen. (See
Figure 2-4
.)
Figure 2-4
BIOS Setup Utility
Note
Your navigating options are provided at the bottom of the screen.
Tab = Jump to next field
Ctrl-E = Down arrow
Ctrl-X = Up arrow
Ctrl-H = Erase (Backspace might not work if your terminal is not configured properly.)