S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
23-4
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
OL-9285-05
Chapter 23 Troubleshooting SANTap
Initial Troubleshooting Checklist
Common Troubleshooting Tools in Fabric Manager
Use the following Fabric Manager procedures to verify the VSAN configuration for the SANTap
components.
•
Choose
Fabric
xx
> VSAN
xx
to view the VSAN configuration in the Information pane.
•
Choose
Fabric
xx
> VSAN
xx
and select the
Host
or
Storage
tab in the Information pane to view the
VSAN members.
Common Troubleshooting Commands in the CLI
Use the
show santap module
command to display information about SANTap.
Example 23-1 Display SANTap CVT Information
switch#
show santap module 2 cvt
CVT Information :
cvt pwwn = 23:4f:00:0d:ec:09:3c:02
cvt nwwn = 23:9d:00:0d:ec:09:3c:02
cvt id = 135895180
cvt xmap_id = 135895212
cvt vsan = 8
cvt name =
Example 23-2 Display SANTap DVT Information
switch#
show santap module 2 dvt
DVT Information :
dvt pwwn = 50:06:0e:80:03:81:32:36
dvt nwwn = 50:06:0e:80:03:81:32:36
dvt id = 136773180
dvt mode = 3
dvt vsan = 12
dvt if_index = 0x1080000
dvt fp_port = 1
dvt name = MYDVT
dvt tgt-vsan = 9
dvt io timeout = 10 secs
dvt lun size handling = 0
dvt app iofail behaviour = 1
dvt quiesce behavior = 1
dvt tgt iofail behavior = 0
dvt appio failover time = 50 secs
dvt inq data behavior = 0
Example 23-3 Display SANTap DVT LUN Information
switch#
show santap module 2 dvtlun
DVT LUN Information :
dvt pwwn = 22:00:00:20:37:88:20:ef
dvt lun = 0x0
xmap id = 8