Service Mode > COPIER > ADJUST (Adjustment Mode) > HV-TR
Service Mode > COPIER > ADJUST (Adjustment Mode) > HV-TR
COPIER> ADJUST> HV-TR
1TR-TGT3
Adj of prmry trnsfer target current(Ev2)
Lv.2 Details
To set the target current that is applied to the primary transfer roller
under the condition of absolute moisture ratio from 1.73 to 5.79 g/m
3
.
When mottled image occurs, increase the current and when water-
drop mark occurs, decrease the current.
As the value is increased by 1, the current is increased by 5 uA.
+: Increase
-: Decrease
Use case
When the image failure due to primary transfer occurs (related to
mottled image, water-drop mark)
Adj/set/operate method Enter the setting value and press OK key.
Caution
Increase/decrease the value 1 by 1 and check the symptom each
time. If too large value is set, high-voltage mottled image occurs.
Display/adj/set range
-10 to 10
Unit
5 uA
Default value
0
1TR-TGT4
Adj of prmry trnsfer target current(Ev3)
Lv.2 Details
To set the target current that is applied to the primary transfer roller
under the condition of absolute moisture ratio from 5.8 to 8.89 g/m
3
.
When mottled image occurs, increase the current and when water-
drop mark occurs, decrease the current.
As the value is increased by 1, the current is increased by 5 uA.
+: Increase
-: Decrease
Use case
When the image failure due to primary transfer occurs (related to
mottled image, water-drop mark)
Adj/set/operate method Enter the setting value and press OK key.
Caution
Increase/decrease the value 1 by 1 and check the symptom each
time. If too large value is set, high-voltage mottled image occurs.
Display/adj/set range
-10 to 10
Unit
5 uA
Default value
0
COPIER> ADJUST> HV-TR
1TR-TGT5
Adj of prmry trnsfer target current(Ev4)
Lv.2 Details
To set the target current that is applied to the primary transfer roller
under the condition of absolute moisture ratio from 8.9 to 14.9 g/m
3
.
When mottled image occurs, increase the current and when water-
drop mark occurs, decrease the current.
As the value is increased by 1, the current is increased by 5 uA.
+: Increase
-: Decrease
Use case
When the image failure due to primary transfer occurs (related to
mottled image, water-drop mark)
Adj/set/operate method Enter the setting value and press OK key.
Caution
Increase/decrease the value 1 by 1 and check the symptom each
time. If too large value is set, high-voltage mottled image occurs.
Display/adj/set range
-10 to 10
Unit
5 uA
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 1TR-TGT1, 1TR-TGT2, 1TR-TGT3,
1TR-TGT4, 1TR-TGT6, 1TR-TGT7, 1TR-TGT8
1TR-TGT6
Adj of prmry trnsfer target current(Ev5)
Lv.2 Details
To set the target current that is applied to the primary transfer roller
under the condition of absolute moisture ratio from 15 to 17.9 g/m
3
.
When mottled image occurs, increase the current and when water-
drop mark occurs, decrease the current.
As the value is increased by 1, the current is increased by 5 uA.
+: Increase
-: Decrease
Use case
When the image failure due to primary transfer occurs (related to
mottled image, water-drop mark)
Adj/set/operate method Enter the setting value and press OK key.
Caution
Increase/decrease the value 1 by 1 and check the symptom each
time. If too large value is set, high-voltage mottled image occurs.
Display/adj/set range
-10 to 10
Unit
5 uA
Default value
0
Related service mode
COPIER> ADJUST> HV-TR> 1TR-TGT1, 1TR-TGT2, 1TR-TGT3,
1TR-TGT4, 1TR-TGT5, 1TR-TGT7, 1TR-TGT8
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...