9
9
9-53
9-53
Installation > Installation > Image position adjustment
Installation > Installation > Image position adjustment
Image position adjustment
NOTE:
In service mode, enter the 1st side value into left field and the 2nd side value into right
side.
1. Skew adjustment
1) Use a magnifying glass (CK-0056) to measure L1 and L2 for right edge margin on the test
print. Adjustment is on 0.05 mm basis.
2) Figure the skew adjustment amount by the following formula:
Skew adjustment amount R = (L2 - L1) / Lx X 15200
(Round off the decimals)
If the skew adjustment amount R is 0.2 or more (R >/= 0.2, R </= -0.2), execute step 3).
3) Enter the value in the following service mode.
Service mode > COPIER > ADJUST > FEED-ADJ > REG-SKEW
F-9-114
2. Magnification ratio adjustment in main scanning direction
1) Measure the image length Ly in main scanning direction on the test print.
Ly
2) Calculate the magnification ratio in main scanning direction (ratio): My, and the value to
enter in Service Mode: SMy.
My = (Ly' / Ly) X 100
A3 paper: Ly’ = 292 mm
11 x 17 inch paper: Ly’ = 274 mm
SMy = (My - 100) X 100
3) Enter SMy value in Service Mode as follows (Do subtraction if SMy is negative value)
Get in Service Mode to select the following: COPIER > ADJUST > IMG-REG > MAG-H-K
Adjustment range: -100 to 100
Unit: 0.01%
NOTE:
There is no mechanical adjustment.
F-9-115
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...