7
7
7-208
7-208
Error Code > Alarm Code > Alarm Code Details
Error Code > Alarm Code > Alarm Code Details
Location Code
Description
Detailed description
30
- 0015 Leakage in secondary
transfer static eliminator
high-voltage
Current leakage is detected.
30
- 0021 ATVC error in primary
transfer
Life is about to end and upper limit is exceeded.
30
- 0025 ATVC error in primary
transfer
Life is about to end and lower limit is exceeded.
30
- 0031 ATVC error in secondary
transfer
Life is about to end and upper limit is exceeded.
30
- 0032 ATVC error in secondary
transfer
Life is about to end and lower limit is exceeded.
30
- 0033 ACVC error in ITB cleaner
downstream
Life is about to end and upper limit is exceeded.
30
- 0034 ACVC error in ITB cleaner
downstream
Life is about to end and lower limit is exceeded.
30
- 0035 ACVC error in ITB cleaner
upstream
Life is about to end and upper limit is exceeded.
30
- 0036 ACVC error in ITB cleaner
upstream
Life is about to end and lower limit is exceeded.
31
- 0006 HDD failure when equipped
with the mirroring function
When it is equipped with the mirroring function,
HDD is broken.
33
- 0010 Stream reading fan alarm
Set: When fan error is detected at the end of job.
Reset: When the fan normally finishes at the end of
job.
33
- 0022 Read motor / Delivery
motor fan alarm
Set: When fan error is detected during job
processing.
Reset: When the fan normally finishes at the end of
job.
33
- 0023 Back side scanner (DADF)
cooling fan 1 alarm
Set: When fan error is detected during job
processing.
Reset: When the fan normally works during job
processing.
33
- 0025 Surface scanner (Reader)
cooling fan 1 alarm
Set: When fan error is detected during job
processing.
Reset: When the fan normally works during job
processing.
34
- 0001 Fine adjustment of auto
registration
Front/rear patch cannot be read.
34
- 0002 Fine adjustment of auto
registration
Correction value per skew adjustment correction
exceeds the limit.
34
- 0004 Fine adjustment of auto
registration
Correction value per writing correction in sub
scanning exceeds the limit.
34
- 0005 Fine adjustment of auto
registration
Sum of correction values of writing correction in sub
scanning exceeds the total limit.
34
- 0006 Fine adjustment of auto
registration
Correction value per writing correction in main
scanning exceeds the limit.
Location Code
Description
Detailed description
34
- 0008 Fine adjustment of auto
registration
Correction value per magnification correction in
main scanning exceeds the limit.
34
- 0009 Fine adjustment of auto
registration
Sum of correction values of magnification correction
in sub scanning exceeds the total limit.
34
- 0101 Adjustment of active
registration
The input skew amount exceeds the acceptable
level for the Active registration area (Registration
unit).
34
- 0102 Adjustment of active
registration
The input horizontal registration amount exceeds
the acceptable level for the Active registration area
(Registration unit).
34
- 0103 Adjustment of active
registration
The input vertical registration amount exceeds the
acceptable level for the Active registration area
(Registration unit).
34
- 0205 Coarse adjustment of auto
registration
Sum of correction values per writing correction in
sub scanning exceeds the total limit.
34
- 0209 Coarse adjustment of auto
registration
Sum of correction values of magnification correction
in sub scanning exceeds the total limit.
34
- 0211 Coarse adjustment of auto
registration
Center patch cannot be read.
34
- 0401 Lead edge patch detection
area at adjustment of
registration detection light
intencity
ITB gross decrease is detected.
34
- 0412 Center registration sensor
area at adjustment of
registration detection light
intencity
ITB gross decrease is detected.
37
- 0001 For R&D
For R&D
37
- 0002 For R&D
For R&D
37
- 0003 For R&D
For R&D
37
- 0004 For R&D
For R&D
37
- 0005 For R&D
For R&D
37
- 0006 For R&D
For R&D
37
- 0007 For R&D
For R&D
37
- 1000 For R&D
For R&D
37
- 2000 For R&D
For R&D
50
- 0007 Post separation sensor is
lack of light intensity
Set: When the light intensity is insufficient at
adjustment.
Reset: Operation terminates normally at the next
adjustment.
50
- 0008 Read sensor is lack of light
intensity
Set: When the light intensity is insufficient at
adjustment.
Reset: Operation terminates normally at the next
adjustment.
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...