Code
Detail
Code
Location
Item
Description
E860 0001 21
Title
Error in power cooling fan 1 (FM2)
Description
of detection
Lock signal of power cooling fan 1 (FM2) is detected.
Measures 1. Check the connector of the power cooling fan 1 (FM2), and
replace the fan if necessary.
2. Replace the multi inserter controller PCB (PCB1).
E860 0002 11
Title
Error in power cooling fan 2 (FM3)
Description
of detection
Lock signal of power cooling fan 2 (FM3) is detected.
Measures 1. Check the connector of the power cooling fan 2 (FM3), and
replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0002 12
Title
Error in power cooling fan 2 (FM3)
Description
of detection
Lock signal of power cooling fan 2 (FM3) is detected.
Measures 1. Check the connector of the power cooling fan 2 (FM3), and
replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0002 13
Title
Error in power cooling fan 2 (FM3)
Description
of detection
Lock signal of power cooling fan 2 (FM3) is detected.
Measures 1. Check the connector of the power cooling fan 2 (FM3), and
replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0002 21
Title
Error in power cooling fan 2 (FM3)
Description
of detection
Lock signal of power cooling fan 2 (FM3) is detected.
Measures 1. Check the connector of the power cooling fan 2 (FM3), and
replace the fan if necessary.
2. Replace the multi inserter controller PCB (PCB1).
E860 0003 11
Title
Error in power cooling fan 1 (FM2)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 1 (FM2), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0003 12
Title
Error in power cooling fan 1 (FM2)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 1 (FM2), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
Code
Detail
Code
Location
Item
Description
E860 0003 13
Title
Error in power cooling fan 1 (FM2)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 1 (FM2), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0003 21
Title
Error in power cooling fan 1 (FM2)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 1 (FM2), and replace the fan if necessary.
2. Replace the multi inserter controller PCB (PCB1).
E860 0004 11
Title
Error in power cooling fan 2 (FM3)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 2 (FM3), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0004 12
Title
Error in power cooling fan 2 (FM3)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 2 (FM3), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0004 13
Title
Error in power cooling fan 2 (FM3)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 2 (FM3), and replace the fan if necessary.
2. Replace the POD deck controller PCB (PCB1).
E860 0004 21
Title
Error in power cooling fan 2 (FM3)
Description
of detection
The lock status is released when the fan stops.
Measures 1. Check the connection/caught cable of the power cooling
fan 2 (FM3), and replace the fan if necessary.
2. Replace the multi inserter controller PCB (PCB1).
E861 0001 11
Title
Error in upper deck communication
Description
of detection
Communication cannot be made between POD deck
controller PCB (PCB1) and POD upper deck pickup drive
driver PCB (PCB36).
Measures 1. Replace the POD upper deck pickup drive driver PCB
(PCB601).
2. Replace the POD deck controller PCB (PCB1).
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...