8
8
8-161
8-161
Service Mode > COPIER > ADJUST (Adjustment Mode) > ADJ-XY
Service Mode > COPIER > ADJUST (Adjustment Mode) > ADJ-XY
ADJUST (Adjustment Mode)
■
AE
COPIER> ADJUST> AE
AE-TBL
Chrctr density adj at image density adj
Lv.1 Details
To adjust the character density according to the adjusted image
density.
As the greater value is set, the characters get darker.
Use case
When clearing the reader controller PCB RAM.
Adj/set/operate method 1) Enter the setting value.
2) Turn OFF/ON the main power switch.
Caution
After the reader controller PCB RAM is cleared, enter the value in
service label.
Display/adj/set range
1 to 9
Default value
5
T-8-31
■
ADJ-XY
COPIER> ADJUST> ADJ-XY
ADJ-X
Adj of img pstn in book mode: main scan
Lv.1 Details
To adjust the image reading start position (image lead edge position)
in main scanning direction.
When the reader controller PCB is replaced or RAM is cleared, enter
the value in service label.
If the non-image width is larger than the standard value, set the
smaller value.
If the out of original area is copied, set the larger value.
As the value is increased by 1, the image position is shifted by 0.1
mm toward the rear.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, enter the changed value in the
service label.
Display/adj/set range
1 to 100
Unit
0.1 mm
Default value
29
ADJ-Y
Img pstn adj if prsre plt is scnd:mn scn
Lv.1 Details
To adjust the image reading start position in main scanning direction.
When the reader controller PCB is replaced or RAM is cleared, enter
the value of service label.
As the value is increased by 1, the start position is shifted by 0.1 mm
toward rear.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting value is changed, enter the changed value in the
service label.
Display/adj/set range
36 to 236
Unit
0.1 mm
Default value
116
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...