7
7
7-60
7-60
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E57C 8002 52
Title
Error in lock of trail-edge retaining motor (M29) of the 2nd
stacker
Description
of detection
Trail-edge retaining HP sensor (S49) failed to be OFF even
though specified period of time has passed in the case of
initial retaining operation
Measures 1. Replace the trail-edge retaining HP sensor (S49).
2. Replace the trail-edge retaining motor (M29).
3. Replace the slave controller PCB.
E57D 8001 51
Title
Error in lock of trail-edge retaining shift motor (M17) of the
stacker
Description
of detection
Trail-edge retaining shift HP sensor (S46) failed to be OFF
even though specified period of time has passed in the case
of initial operation to shift from HP to stack tray 2
Measures 1. Check the connector of the trail-edge retaining shift HP
sensor (S46), and replace the sensor if necessary.
2. Replace the trail-edge retaining motor (M29).
3. Replace the slave controller PCB.
E57D 8001 52
Title
Error in lock of trail-edge retaining shift motor (M17) of the
2nd stacker
Description
of detection
Trail-edge retaining shift HP sensor (S46) failed to be OFF
even though specified period of time has passed in the case
of initial operation to shift from HP to stack tray 2
Measures 1. Check the connector of the trail-edge retaining shift HP
sensor (S46), and replace the sensor if necessary.
2. Replace the trail-edge retaining motor (M29).
3. Replace the slave controller PCB.
E57D 8002 51
Title
Error in lock of trail-edge retaining shift motor (M17) of the
stacker
Description
of detection
Trail-edge retaining shift HP sensor (S46) failed to be OFF
even though specified period of time has passed in the case
of initial operation to shift from stack tray 2 to HP
Measures 1. Replace the trail-edge retaining shift HP sensor (S46).
2. Replace the trail-edge retaining motor (M29).
3. Replace the Slave controller PCB.
E57D 8002 52
Title
Error in lock of trail-edge retaining shift motor (M17) of the
2nd stacker
Description
of detection
Trail-edge retaining shift HP sensor (S46) failed to be OFF
even though specified period of time has passed in the case
of initial operation to shift from stack tray 2 to HP
Measures 1. Replace the trail-edge retaining shift HP sensor (S46).
2. Replace the trail-edge retaining motor (M29).
3. Replace the Slave controller PCB.
Code
Detail
Code
Location
Item
Description
E580 8011
51
Title
Error in lock of stack tray up/down motor 1 (M20) of the
stacker
Description
of detection
In the case that stack tray 1 full level sensor (S18) and arm
escape sensor 1 (S19) are ON, although turning OFF of stack
tray 1 full level sensor (S18) triggers to stop lowering of the
stack tray, it failed to be OFF even though 30sec has passed.
Measures 1. Replace the stack tray up/down motor 1 (M20).
2. Replace the slave controller PCB.
E580 8011
52
Title
Error in lock of stack tray up/down motor 1 (M20) of the 2nd
stacker
Description
of detection
In the case that stack tray 1 full level sensor (S18) and arm
escape sensor 1 (S19) are ON, although turning OFF of stack
tray 1 full level sensor (S18) triggers to stop lowering of the
stack tray, it failed to be OFF even though 30sec has passed.
Measures 1. Replace the stack tray up/down motor 1 (M20).
2. Replace the slave controller PCB.
E580 8012 51
Title
Error in lock of stack tray up/down motor 1 (M20) of the
stacker
Description
of detection
In the case that stack tray 2 full level sensor (S23) is ON
while arm escape sensor 1 (S19) is OFF, although turning ON
of arm escape sensor 1 (S19) triggers to stop lowering of the
stack tray, it failed to be ON even though 30 sec has passed.
Measures 1. Check the connector of the arm escape sensor 1 (S19),
and replace the sensor if necessary.
2. Replace the stack tray up/down motor 1 (M20).
3. Replace the slave controller PCB.
E580 8012 52
Title
Error in lock of stack tray up/down motor 1 (M20) of the 2nd
stacker
Description
of detection
In the case that stack tray 2 full level sensor (S23) is ON
while arm escape sensor 1 (S19) is OFF, although turning ON
of arm escape sensor 1 (S19) triggers to stop lowering of the
stack tray, it failed to be ON even though 30 sec has passed.
Measures 1. Check the connector of the arm escape sensor 1 (S19),
and replace the sensor if necessary.
2. Replace the stack tray up/down motor 1 (M20).
3. Replace the slave controller PCB.
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...