8
8
8-25
8-25
Service Mode > COPIER > DISPLAY (Status Display Mode) > ANALOG
Service Mode > COPIER > DISPLAY (Status Display Mode) > ANALOG
COPIER> DISPLAY> ANALOG
MI1-TEMP
Temperature of multi inserter storage
Lv.1 Details
Displaying temperature in the deck of the multi insertion unit.
Measured by the environment sensor that detects the deck.
Use case
When checking temperature in the deck.
Adj/set/operate method N/A (display only)
Unit
Degree C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> DK1-TEMP, DK2-TEMP, DK3-
TEMP
DK3-TEMP
Dspl of inside temperature of POD deck3
Lv.1 Details
Displaying temperature inside the 2nd secondary POD deck storage.
Measured by the environment sensor (HS601) found at the upper
deck.
Use case
When checking the temperature inside the storage.
Adj/set/operate method N/A (display only)
Unit
Degree C
Appropriate target value 20 to 27
Related service mode
COPIER> DISPLAY> ANALOG> DK1-TEMP, DK2-TEMP
DK3-HUM
Dspl of inside humidity of POD deck3
Lv.1 Details
Displaying humidity inside the 2nd secondary POD deck storage.
Measured by the environment sensor (HS601) found at the upper
deck.
Use case
When checking the humidity inside the storage.
Adj/set/operate method N/A (display only)
Unit
%
Appropriate target value 30 to 70
Related service mode
COPIER> DISPLAY> ANALOG> DK1-HUM, DK2-HUM
T-8-6
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...