Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Code
Detail
Code
Location
Item
Description
E5B0 8001 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
Temperature detection thermistor (S56) cannot detect setting
tempe/- 5 degree C within 600 sec after energy
conversation mode is released.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature detection thermistor (S56).
3. Replace the slave controller PCB.
E5B0 8002 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The temperature detection thermistor (S56) detected a
temperature more than 200 degree C in 1 sec.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature detection thermistor (S56).
3. Replace the slave controller PCB.
E5B0 8003 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The temperature detection thermistor (S56) detected a
temperature below than 5 degree C in 1 sec. (Detection starts
10 sec after activation)
Measures 1. Replace the heater (HTR1).
2. Replace the temperature detection thermistor (S56).
3. Replace the slave controller PCB.
E5B0 8004 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The temperature detection thermistor (S56) cannot detect
more than 140 degree C within 200 sec after detecting 50
degree C.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature detection thermistor (S56).
3. Replace the slave controller PCB.
E5B0 8005 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The temperature detection thermistor (S56) detected
temperature below than 135 degree C more than 10 sec after
the temperature adjustment is finished.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature detection thermistor (S56).
3. Replace the slave controller PCB.
E5B0 8006 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The Error in the temperature error detection thermistor (S57)
is detected.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature error detection thermistor (S57).
3. Replace the slave controller PCB.
E5B0 8007 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
Error in thermostat (THSW) is detected.
Measures 1. Replace the heater (HTR1).
2. Replace the thermistor (THSW).
3. Replace the slave controller PCB.
Code
Detail
Code
Location
Item
Description
E5B0 8008 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The remain detection thermistor (S58) detected temperature
more than 170 degree C more than 10 seconds after warm
up is finished.
Measures 1. Replace the heater (HTR1).
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
E5B0 8009 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The remain detection thermistor (S58) detected temperature
below than 171 degree C more than 10 seconds after warm
up is finished.
Measures 1. Replace the heater (HTR1).
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
E5B0 800B 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The temperature error detection thermistor (S57) detected
disconnection.
Measures 1. Replace the heater (HTR1).
2. Replace the temperature error detection thermistor (S57).
3. Replace the slave controller PCB.
E5B0 800C 61
Title
Error in the heater (HTR1) on the perfect binder.
Description
of detection
The remain detection thermistor (S58) detected
disconnection.
Measures 1. Replace the heater (HTR1).
2. Replace the remain detection thermistor (S58).
3. Replace the slave controller PCB.
E5B0 800D 61
Title
The Error in the internal temperature of the perfect binder.
Description
of detection
The internal temperature thermistor (S105) detected
temperature more than 80 degree C in 1 sec.
Measures 1. Replace the internal temperature thermistor (S105).
2. Replace the slave controller PCB.
E5B0 800E 61
Title
The Error in the internal temperature of the perfect binder.
Description
of detection
The internal temperature thermistor (S105) detected
disconnection.
Measures 1. Replace the internal temperature thermistor (S105).
2. Replace the slave controller PCB.
E5B0 800F 61
Title
The Error in the internal temperature of the perfect binder.
Description
of detection
There is more than 10 degree C gap, in the time longer than
some specified time, between 1 minute fixed data of the
internal thermistor (S105) and 1 sec raw data,
Measures 1. Replace the internal temperature thermistor (S105).
2. Replace the slave controller PCB.
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...