6
6
6-57
6-57
Troubleshooting > Version Upgrade > Uploading and Downloading Backup Data > Downloading Procedure
Troubleshooting > Version Upgrade > Uploading and Downloading Backup Data > Downloading Procedure
■
Downloading Procedure
CAUTION :
• The file SramImg.bin, MeapBack or SramRCON may only be downloaded to their
source machine.
• The point to keep in mind of the Inbox: Before replacing the Main Controller PCB 2,
back up Sraming.bin using SST. After replacing the Main Controller PCB 2, be sure
to start the machine with the 2 and 8 keys in safe mode, and restore Sraming.bin
using SST. If the machine is started normally without restoring Sraming.bin at the
first startup, a mismatch occurs between the Inbox management information in the
SRAM of the Main Controller PCB 2 and the Inbox data in the HDD.
In that case,
the documents in the Inbox are lost and cannot be opened.
• The machine must be in safe mode for downloading the file MeapBack.
• The machine must be in normal mode for downloading the file SramRCON.
Here is the MeapBack download procedure as an example.
1) Start the machine in safe mode. (While pressing 2 + 8, turn ON the main power switch.)
2) Start up the SST.
3) Select the model and the type of system software ('Single') ; then, check the network
settings, and click [START].
MFP
USB
Target Selection
CONTROL
Export Firm Selection
iPR1135
MFP
USB
c:
Interface
Network
IP Address
172.16.1.100
EXIT
START
Register Firmware
CONNECT
Delete Firmware
Delete Backup Data
System Management
Select the target.
Click a button to execute.
Register
Remove
Click the interface and click the [START]
button.
Service Support Tool DLM0 (Ver. X.XX E)
iPR1135
Single
ALL
Start Assist Mode
Select the model
Type of system software
F-6-94
4) Click [Download Data].
SelectableFirmware
Control
172.16.1.100
iPR1135
SAFE
SYSTEM
iPR1135
Hold
USenXXXXM
Backup
USenXXXXW
MEAPCONT
XXxxXXXX
SDICT
XXjaXXXX
RUI
XXenXXXX
LANGUAGE
XXenXXXX
XXjaXXXX
ASR
iPR1135
BROWSER
DCON
HELP
LANGUAGE
MEAPCONT
MEDIA
RCON
RUI
SYSTEM
TTS
WebDAV
SelectableFirmware
Select the firmware to be downloaded,
then click the [Start] button.
ServiceSupportTool DLM10 (Ver. X.XX E)
Click the button of the task to be
executed.
Download Firmware
Upload Data
Download Data
Restore Backup System
Format HDD
Shutdown
Return to Main Menu
Start
Clear
KEY
iRZZZZ
SDICT
5) Select the data to download, and click [Start].
172.16.1.100
iPR1135
SAFE
Control
FileSave
SelectableDate
Select the file to be downloaded, then
click the [Start] button.
c:
DataType : backup of meap
Date : 2008/12/15 17:36:49
Memo : Memo
Serial No : F6310130
Series : iPR1135
MeapBack.bin.upd
Clear
Click the button of the task to be
executed.
SramRCON.bin.upd
ServiceSupportTool DLM10 (Ver. X.XX E)
Download Firmware
Upload Data
Download Data
Restore Backup System
Format HDD
Cancel
Return to Main Menu
Start
6) When downloading has ended, click [OK] to return to the previous screen.
F-6-95
F-6-96
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...