E5B4 8002 52
Title
DA error in gripper HP sensor (S15) of the 2nd stacker
Description
of detection
When adjusting sensor, AD entry for gripper HP sensor (S15)
failed to be within the adjustment range although making DA
output larger than the upper limit.
Measures 1. Check the connector of the gripper HP sensor (S15), and
replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8002 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the cover registration sensor
(S21) changed up to the upper limit value, the A/D input limit
can’t get within the set range.
Measures 1. Clean the cover registration sensor (S21), and replace the
sensor if necessary.
2. Replace the master controller PCB.
E5B4 8003 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the cover side registration
sensor (S) (S71) changed up to the upper limit value, the A/D
input limit can’t get within the set range.
Measures 1. Clean the cover side registration sensor (S) (S71), and
replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8004 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the cover side registration
sensor (L) (S72) changed up to the upper limit value, the A/D
input limit can’t get within the set range.
Measures 1. Clean the cover side registration sensor (L) (S72), replace
the sensor if necessary.
2. Replace the slave controller PCB.
E5B4 8005 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the stack delivery sensor (S64T/
S64L) changed up to the upper limit value, the A/D input limit
can’t get within the set range.
Measures 1. Clean the stack delivery sensor (S64T/S64L), replace the
sensor if necessary.
2. Replace the slave controller PCB.
E5B4 8006 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the leading edge detection
sensor (S65T/S65L) changed up to the upper limit value, the
A/D input limit can’t get within the set range.
Measures 1. Clean the leading edge detection sensor (S65T/S65L), and
replace the sensor if necessary.
2. Replace the slave controller PCB.
Code
Detail
Code
Location
Item
Description
E5B4 8007 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the input path sensor (S92T/
S92L) changed up to the upper limit value, the A/D input limit
can’t get within the set range.
Measures 1. Clean the inlet path sensor (S92T/S92L), and replace the
sensor if necessary.
2. Replace the cutter controller PCB.
E5B4 8008 61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the registration sensor (S88T/
S88L) changed up to the upper limit value, the A/D input limit
can’t get within the set range.
Measures 1. Clean the registration sensor (S88T/S88L), and replace the
sensor if necessary.
2. Replace the cutter controller PCB.
E5B4 8011
51
Title
DA error in side registration shift sensor (S1) of the stacker
Description
of detection
When adjusting sensor, AD entry for side registration shift
sensor (S1) failed to be within the adjustment range although
making DA output smaller than the upper limit.
Measures 1. Check the connector of the side registration shift sensor
(S1), and replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8011
52
Title
DA error in side registration shift sensor (S1) of the 2nd
stacker
Description
of detection
When adjusting sensor, AD entry for side registration shift
sensor (S1) failed to be within the adjustment range although
making DA output smaller than the upper limit.
Measures 1. Check the connector of the side registration shift sensor
(S1), and replace the sensor if necessary.
2. Replace the master controller PCB.
E5B4 8011
61
Title
Error in the sensor auto adjustment of the perfect binder.
Description
of detection
Even the D/A output value of the timing sensor (S5) changed
up to the lower limit value, the A/D input limit can’t get within
the set range.
Measures 1. Replace the timing sensor (S5).
2. Replace the master controller PCB.
E5B4 8012 51
Title
DA error in gripper HP sensor (S15) of the stacker
Description
of detection
When adjusting sensor, AD entry for gripper HP sensor (S15)
failed to be within the adjustment range although making DA
output smaller than the upper limit.
Measures 1. Check the connector of the gripper HP sensor (S15), and
replace the sensor if necessary.
2. Replace the master controller PCB.
Содержание imagePRESS 1110
Страница 242: ...3 3 Periodical Service Periodical Service Periodical service item ...
Страница 655: ...5 5 Adjustment Adjustment Overview When replacing parts Major adjustment ...
Страница 733: ...7 7 Error Code Error Code Overview Location Code Pickup Position Code Pickup size Error Code Jam Code Alarm Code ...
Страница 944: ...8 8 Service Mode Service Mode Overview COPIER FEEDER SORTER BOARD Situation Mode ...
Страница 1555: ... Service Tools General Circuit Diagram General Timing Chart Operator Maintenance Appendix ...